Amperometric detection of glucose using self-catalytic carbon paste electrodes

被引:15
作者
Evans, RG [1 ]
Banks, CE [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.1039/b402091j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical detection of D-glucose by means of self-catalytic carbon paste electrodes is described. In the construction of these electrodes, carbon powder has been modified with the redox liquid n-butylferrocene, which simultaneously serves both to help bind the paste together whilst also acting as a mediator in the enzymatic oxidation of D-glucose by glucose oxidase. The sensor then functions by monitoring the electrochemical oxidation of the constituent n-butylferrocene itself. Through testing in model glucose solutions, the electrodes were found to yield a linear response over a D-glucose concentration range of 2-20 mM. They were also successfully employed in the determination of D- glucose levels in a spiked blood sample, giving a detection limit of 0.8 mM ( based on the 3sigma criterion).
引用
收藏
页码:428 / 431
页数:4
相关论文
共 22 条
  • [1] CARBON PASTE ELECTRODES
    ADAMS, RN
    [J]. ANALYTICAL CHEMISTRY, 1958, 30 (09) : 1576 - 1576
  • [2] Electrochemistry of immobilised redox droplets: Concepts and applications
    Banks, CE
    Davies, TJ
    Evans, RG
    Hignett, G
    Wain, AJ
    Lawrence, NS
    Wadhawan, JD
    Marken, F
    Compton, RG
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2003, 5 (19) : 4053 - 4069
  • [3] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [4] Kaisheva A., 1994, BULG CHEM COMMUN, V27, P598
  • [5] CHEMICALLY MODIFIED CARBON PASTE ELECTRODES IN VOLTAMMETRIC ANALYSIS
    KALCHER, K
    [J]. ELECTROANALYSIS, 1990, 2 (06) : 419 - 433
  • [6] SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993
    KALCHER, K
    KAUFFMANN, JM
    WANG, J
    SVANCARA, I
    VYTRAS, K
    NEUHOLD, C
    YANG, Z
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 5 - 22
  • [7] STUDY OF THE NEW ELECTRON-TRANSFER MEDIATORS IN GLUCOSE-OXIDASE CATALYSIS
    KULYS, J
    BUCHRASMUSSEN, T
    BECHGAARD, K
    RAZUMAS, V
    KAZLAUSKAITE, J
    MARCINKEVICIENE, J
    CHRISTENSEN, JB
    HANSEN, HE
    [J]. JOURNAL OF MOLECULAR CATALYSIS, 1994, 91 (03): : 407 - 420
  • [8] Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
    Liu, SQ
    Ju, HX
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) : 177 - 183
  • [9] Carbon ceramic electrode modified with redox liquid
    Opallo, M
    Saczek-Maj, M
    [J]. CHEMICAL COMMUNICATIONS, 2002, (05) : 448 - 449
  • [10] Raoof JB, 2003, B ELECTROCHEM, V19, P17