The effect of off-the-visual-axis retinoscopy on objective refractive measurement

被引:20
作者
Jackson, DW
Paysse, EA
Wilhelmus, KR
Hussein, MAW
Rosby, G
Coats, DK
机构
[1] Baylor Coll Med, Texas Childrens Hosp, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[2] Baylor Coll Med, Texas Childrens Hosp, Cullen Eye Inst, Dept Pediat, Houston, TX 77030 USA
关键词
D O I
10.1016/j.ajo.2004.02.012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the effect of off,axis retinoscopy on objective refractive measurement. DESIGN: Prospective experimental study. METHODS: Eight volunteers underwent cycloplegic retinoscopy of their right eye on-the-visual-axis, and 5, 10, 15, and 20 degrees off-the-visual-axis in adduction. A single masked examiner performed all retinoscopy with random order of the patient and axis refracted. RESULTS: The average spherical retinoscopic value at 0, 5,10,15, and 20 degrees of off-axis alignment was -0.40, -0.90, -1.00, -1.38, and -1.80 diopters, respectively. The average spherical equivalent retinoscopic value obtained for each of the above positions of eye alignment was -0.02, -0.59, -0.45, -0.64, and -0.98 diopters, respectively. The induced cylinder power increased by an average of 3% for each degree of off-axis retinoscopy, though the axis of the cylinder was not predictable. CONCLUSION: Objective refractive measurement by retinoscopy is significantly altered by off-the visual,axis retinoscopy. The induced error may be clinically important even with small degrees of eccentricity. (C) 2004 by Elsevier Inc. All rights reserved.
引用
收藏
页码:1101 / 1104
页数:4
相关论文
共 18 条
[1]  
Abrams D., 1993, DUKE ELDERS PRACTICE, V10th, P164
[2]  
BENJAMIN W, 1988, BORISHS CLIN REFRACT, P582
[3]   B-mode-guided vector-A-mode versus A-mode biometry to determine axial length and intraocular lens power [J].
Berges, O ;
Puech, M ;
Assouline, M ;
Letenneur, L ;
Gastellu-Etchegorry, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (04) :529-535
[4]   CLASSIFICATION OF NORMAL CORNEAL TOPOGRAPHY BASED ON COMPUTER-ASSISTED VIDEOKERATOGRAPHY [J].
BOGAN, SJ ;
WARING, GO ;
IBRAHIM, O ;
DREWS, C ;
CURTIS, L .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :945-949
[6]  
Ferree CE, 1931, ARCH OPHTHALMOL-CHIC, V5, P717
[7]   Interpretation of refractive conditions in the peripheral field of vision - A further study [J].
Ferree, CE ;
Rand, G .
ARCHIVES OF OPHTHALMOLOGY, 1933, 9 (06) :925-938
[8]  
Ferree CE, 1932, AM J OPHTHALMOL, V15, P513, DOI 10.1016/S0002-9394(32)90740-5
[9]  
HOLLADAY JT, 1992, REFRACTIVE KERATOTOM, P47
[10]   Computer modeling of visual impairment caused by intraocular lens misalignment [J].
Korynta, J ;
Bok, J ;
Cendelin, J ;
Michalova, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (01) :100-105