Functional magnetic resonance imaging in a stereotactic setup

被引:15
作者
Debus, J [1 ]
Essig, M [1 ]
Schad, LR [1 ]
Wenz, F [1 ]
Baudendistel, K [1 ]
Knopp, MV [1 ]
Engenhart, R [1 ]
Lorenz, WJ [1 ]
机构
[1] UNIV HEIDELBERG,DEPT RADIOTHERAPY,HEIDELBERG,GERMANY
关键词
magnetic resonance imaging; techniques; functional imaging; stereotactic immobilization; treatment planning; motor cortex stimulation;
D O I
10.1016/S0730-725X(96)02108-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRT (fMRI) in a stereotactic set-up. The skull of the patients has been immobilized for stereotactic treatment planning either with a self developed stereotactic ceramic frame and bony fixation or with an individual precision mask system made of light cast. It has been shown that this frame does not produce any image distortion. fMRI was performed using a modified FLASH sequence on a conventional 1.5 T MRI scanner with a specially developed linear polarized head coil. The imaging technique used was an optimized conventional 2D and 3D, first order how rephased, gradient echo sequence (FLASH) with fat-suppression and reduce bandwidth (16-28 Hz/pixel) and TR = 80-120 ms, TE = 60 ms, hip angle = 40 degrees, matrix = 128 x 128, FOV = 150-250 mm, slice-thickness = 2-5 mm, NEX = 1, and a total single scan time for one image of about 7 sec. The motor cortex stimulation was achieved by touching each finger to thumb in a sequential, self-paced, and repetitive manner. Statistical parametric maps based on student's test were calculated, Pixels with a highly significant signal increase (p < 0.001) are overlaid on T1w SE images. The primary motor and sensory cortex could be visualized with this method in all 10 patients that were imaged in this study. Due to tight fixation of the patient's skull there have been no motion artifacts. These results show that functional MRT is feasible in an stereotactic set-up with an standard 1.5 T scanner. This is a prerequisite for the exact pre therapeutic assessment of the function of cortical centers. Copyright (C) 1996 Elsevier Science Inc.
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 20 条
[1]   POSTPROCESSING OF FUNCTIONAL MRI DATA OF MOTOR CORTEX STIMULATION MEASURED WITH A STANDARD 1.5 T IMAGER [J].
BAUDENDISTEL, K ;
SCHAD, LR ;
FRIEDLINGER, M ;
WENZ, F ;
SCHRODER, J ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1995, 13 (05) :701-707
[2]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[3]  
CONELLY A, 1993, RADIOLOGY, V188, P125
[4]   FUNCTIONAL BRAIN IMAGING AT 1.5-T USING CONVENTIONAL GRADIENT-ECHO MR-IMAGING TECHNIQUES [J].
CONSTABLE, RT ;
MCCARTHY, G ;
ALLISON, T ;
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :451-459
[5]  
Debus J., 1994, International Journal of Radiation Oncology Biology Physics, V30, P265, DOI 10.1016/0360-3016(94)90819-2
[6]   THE ROLE OF HIGH-DOSE, SINGLE-FRACTION IRRADIATION IN SMALL AND LARGE INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS [J].
ENGENHART, R ;
WOWRA, B ;
DEBUS, J ;
KIMMIG, BN ;
HOVER, KH ;
LORENZ, W ;
WANNENMACHER, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (03) :521-529
[7]   FOCAL PHYSIOLOGICAL UNCOUPLING OF CEREBRAL BLOOD-FLOW AND OXIDATIVE-METABOLISM DURING SOMATOSENSORY STIMULATION IN HUMAN-SUBJECTS [J].
FOX, PT ;
RAICHLE, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (04) :1140-1144
[8]   DYNAMIC MR IMAGING OF HUMAN BRAIN OXYGENATION DURING REST AND PHOTIC-STIMULATION [J].
FRAHM, J ;
BRUHN, H ;
MERBOLDT, KD ;
HANICKE, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :501-505
[9]   FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION AT HIGH SPATIAL-RESOLUTION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :139-144
[10]   FRACTIONATED STEREOTAXICALLY GUIDED RADIOTHERAPY OF HEAD AND NECK TUMORS - A REPORT ON CLINICAL USE OF A NEW SYSTEM IN 195 CASES [J].
GADEMANN, G ;
SCHLEGEL, W ;
DEBUS, J ;
SCHAD, L ;
BORTFELD, T ;
HOVER, KH ;
LORENZ, WJ ;
WANNENMACHER, M .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :205-213