Bar code and radio-frequency technologies can increase safety and efficiency of blood transfusions

被引:11
作者
Sandler, SG [1 ]
Langeberg, A
Carty, K
Dohnalek, LJ
机构
[1] Georgetown Univ Hosp, MedStar, Dept Lab Med, Washington, DC 20007 USA
[2] Georgetown Univ Hosp, MedStar, Nursing Serv, Washington, DC 20007 USA
来源
LABMEDICINE | 2006年 / 37卷 / 07期
关键词
D O I
10.1309/QNR1B7310H7376MP
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Bar-coded labels on wristbands blood sample tubes and blood components can facilitate matching the right blood unit and the right patient. Nurses preferred to verify their patient blood unit identification matches by scanning bar code labels rather than seeking out a second nurse for a conventional visual "double check verification Occasional scans of bar coded wristbands failed because of crinkles food spills and blurring due to bathing. Also, inadvertently scanning the wrong bar code on a blood component signaled the program that a mismatch was occurring and shut down the system according to the requirements of our software program Radio frequency identification (RFID) labels on wristbands and blood components were easier to scan but bar coded labels may be adequate for personal identification cards and labels on blood sample tubes for budget-conscious transfusion safety systems. We envision significant advantages to combining transfusion safety and medication dispensing systems using common hardware and complementary software programs.
引用
收藏
页码:436 / 439
页数:4
相关论文
共 14 条
[1]  
*AABB, 2004, STAND BLOOD BANKS TR, P47
[2]   POSITIVE DONOR-RECIPIENT IDENTIFICATION SYSTEM FOR A REGIONAL BLOOD-TRANSFUSION SERVICE [J].
CHAMBERS, RW ;
RUBIN, MI ;
RATH, CE ;
SANDLER, SG ;
BALL, JH .
TRANSFUSION, 1973, 13 (01) :34-36
[3]  
Chan J. C. W., 2004, Hong Kong Medical Journal, V10, P166
[4]  
Dohnalek Laurie J, 2004, Nurs Manage, V35, P33, DOI 10.1097/00006247-200406000-00011
[5]   An automated system for bedside verification of the match between patient identification and blood unit identification [J].
Jensen, NJ ;
Crosson, JT .
TRANSFUSION, 1996, 36 (03) :216-221
[6]  
Marconi M, 2000, Immunohematology, V16, P82
[7]   Barcode identification for transfusion safety [J].
Murphy, MF ;
Kay, JDS .
CURRENT OPINION IN HEMATOLOGY, 2004, 11 (05) :334-338
[8]  
Sandler S, 2005, TRANSFUSION, V45, p86A
[9]   Bar code technology can improve transfusion safety - but barriers to implementation remain [J].
Sandler, SG .
CURRENT OPINION IN HEMATOLOGY, 2003, 10 (06) :403-404
[10]   A fully automated blood typing system for hospital transfusion services [J].
Sandler, SG ;
Langeberg, A ;
Avery, N ;
Mintz, PD .
TRANSFUSION, 2000, 40 (02) :201-207