In vitro assessment of the hemodynamic effects of a partial occlusion in a vena cava filter

被引:21
作者
Couch, GG
Kim, H
Ojha, M
机构
[1] UNIV TORONTO, INST BIOMED ENGN, TORONTO, ON M5S 1A4, CANADA
[2] UNIV TORONTO, DEPT CHEM ENGN & APPL CHEM, TORONTO, ON M5S 1A4, CANADA
[3] UNIV TORONTO, DEPT SURG, TORONTO, ON M5S 1A4, CANADA
[4] BOSTON SCI CORP, BOSTON, MA USA
关键词
WALL SHEAR-STRESS; GREENFIELD FILTER; PULSATILE FLOW; RESOLUTION;
D O I
10.1016/S0741-5214(97)70293-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Flow fields surrounding a vena cava filter were studied with a noninvasive method of flow visualization to examine the underlying hemodynamic factors that contribute to its function and patency. Methods: The photochromic technique was used to measure axial velocity profiles and wall shear stress distributions in a 12F titanium Greenfield filter partially occluded with a simulated volume of entrapped thrombi. These results were compared with similar measurements obtained for an unoccluded filter and with a theoretic prediction of the velocity profile and wall shear stress without a vena cava filter. Shear stress distributions were obtained along the vessel wall and for the partially occluded filter along the surface of the simulated clot. Results: The unoccluded filter was observed to have little effect on the flow field. In the case of the partially occluded filter, the results of these measurements show that caval blood flow is preserved by the creation of an annular region of increased flow around the periphery of the clot. Within this region high shear stresses that develop as a result of the increased flow are observed along the vessel wall and along the surface of the simulated clot. No vortices or turbulence were observed with either the unoccluded or the partially occluded filter. Conclusions: The elevated levels of shear stress may be a factor in the lysis of trapped clots observed in vivo. Although increased shear stress is reported to cause thrombogenesis in an in vivo study in canines, particularly under turbulent flow conditions, the levels of shear measured in this study around the simulated clot were well below such values.
引用
收藏
页码:663 / 672
页数:10
相关论文
共 19 条
[1]  
[Anonymous], 1961, Boundary Layer Theory
[2]  
BECKER DM, 1992, ARCH INTERN MED, V152, P1984
[3]   EXPERIMENTAL COMPARISON OF PERCUTANEOUS VENA-CAVAL DEVICES - TITANIUM GREENFIELD FILTER VERSUS BIRDS NEST FILTER [J].
BURKE, PE ;
MICHNA, BA ;
HARVEY, CF ;
CRUTE, SL ;
SOBEL, M ;
GREENFIELD, LJ .
JOURNAL OF VASCULAR SURGERY, 1987, 6 (01) :66-70
[4]  
CIMOCHOWSKI GE, 1980, J THORAC CARDIOV SUR, V79, P358
[5]  
GEISINGER MA, 1987, RADIOLOGY, V156, P383
[6]  
GREENFIELD LJ, 1973, SURGERY, V73, P599
[7]  
GREENFIELD LJ, 1977, ANN SURG, V185, P692, DOI 10.1097/00000658-197706000-00012
[8]   INFERIOR VENA-CAVA FILTERS - INVITRO COMPARISON OF CLOT TRAPPING AND FLOW DYNAMICS [J].
KATSAMOURIS, AA ;
WALTMAN, AC ;
DELICHATSIOS, MA ;
ATHANASOULIS, CA .
RADIOLOGY, 1988, 166 (02) :361-366
[9]  
Korbin C D, 1992, J Vasc Interv Radiol, V3, P559, DOI 10.1016/S1051-0443(92)72015-6
[10]   INVITRO FLOW PHANTOM ANALYSIS AND CLOT-CAPTURING ABILITY OF INCOMPLETELY OPENED VENA TECH-LGM VENA-CAVAL FILTERS [J].
KORBIN, CD ;
REED, RA ;
TAYLOR, FC ;
KOKORIS, SP ;
TEITELBAUM, GP .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (01) :3-6