An automated and modified technique for testing: the retinal function (Arden test) by use of the electro-oculogram (EOG) for clinical and research use

被引:9
作者
Behrens, F [1 ]
Weiss, LR [1 ]
机构
[1] Free Univ Berlin, Klinikum Benjamin Franklin, Inst Physiol, D-14195 Berlin, Germany
关键词
automated saccade detection; corneo-retinal potential; dark adaptation; modified Arden-index;
D O I
10.1023/A:1001793321991
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The electro-oculogram (EOG) can be recorded by use of skin electrodes positioned near the eye in the horizontal or vertical plane and is dependent on the position of the eye relative to the electrodes and the size of the corneo-retinal potential (CRP). By use of the functional relation between the recorded potential and the eye position - CRP is considered to be constant - the EOG is the eye movement recording method most often used. Changes in CRP dependent on luminance or metabolic influences call be measured, on the other hand, by means of the EOG when eye movements of constant amplitudes are performed. The EOG in this paper is used in the latter sense. The widely used clinical test of rentinal function based on the electro-oculogram firstly described by Arden (Arden index) has been modified to achieve more precise and reliable results by including a gradual dark adaptation procedure and a special data analysis to detect fixation periods. Using modern techniques, the complete procedure has been automated. The efficiency of the procedure and the device is demonstrated in various ways.
引用
收藏
页码:283 / 292
页数:10
相关论文
共 10 条
[1]  
ANDERSON ML, 1980, INVEST OPHTH VIS SCI, V19, P278
[2]  
Arden G B, 1962, Br J Ophthalmol, V46, P449, DOI 10.1136/bjo.46.8.449
[3]   AN ALGORITHM SEPARATING SACCADIC FROM NONSACCADIC EYE-MOVEMENTS AUTOMATICALLY BY USE OF THE ACCELERATION SIGNAL [J].
BEHRENS, F ;
WEISS, LR .
VISION RESEARCH, 1992, 32 (05) :889-893
[4]   REDUCED VARIABILITY IN THE ELECTRO-OCULOGRAM [J].
DAWSON, WM ;
MAIDA, TM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 97 (03) :395-395
[5]   STANDARD FOR CLINICAL ELECTROOCULOGRAPHY [J].
MARMOR, MF ;
ZRENNER, E .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :601-604
[6]   The steady polarity potential of the human eye [J].
Miles, WR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1939, 25 :25-36
[7]  
PETSCH J, 1995, ELRAD, V3, P52
[8]  
SKOOG KO, 1975, ACTA OPHTHALMOL, V53, P710
[9]   OCULAR DIPOLE - DAMPED OSCILLATOR STIMULATED BY SPEED OF CHANGE IN ILLUMINATION [J].
TAUMER, R ;
HENNIG, J ;
PERNICE, D .
VISION RESEARCH, 1974, 14 (08) :637-645
[10]  
van Lith G H, 1970, Acta Ophthalmol (Copenh), V48, P1091