Interpolation artefacts in mutual information-based image registration

被引:202
作者
Pluim, JPW [1 ]
Maintz, JBA [1 ]
Viergever, MA [1 ]
机构
[1] Univ Utrecht, Med Ctr, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
关键词
image registration; mutual information maximization; linear interpolation; partial volume interpolation; interpolation artefacts;
D O I
10.1006/cviu.1999.0816
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Image registration requires the transformation of one image to another so as to spatially align the two images, This involves interpolation to estimate gray values of one of the images at positions other than the grid points. When registering two images that have equal grid distances in one or more dimensions, the grid points can be aligned in those dimensions for certain geometric transformations. Consequently, the number of times interpolation is required to compute the registration measure of two images is dependent on the image transformation, When an entropy-based registration measure, such as mutual information, is plotted as a function of the transformation, it will show sudden changes in value for grid-aligning transformations, Such patterns of local extrema impede the registration optimization process, More importantly, they rule out subvoxel accuracy. In this paper, two frequently applied interpolation methods in mutual information-based image registration are analyzed, viz. linear interpolation and partial volume interpolation, It is shown how the registration function depends on the interpolation method and how a slight resampling of one of the images may drastically improve the smoothness of this function, (C) 2000 Academic Press.
引用
收藏
页码:211 / 232
页数:22
相关论文
共 17 条
[1]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[2]  
COLLIGNON A, 1995, COMP IMAG VIS, V3, P263
[3]  
COLLIGNON A, 1998, THESIS CATHOLIC U LE
[4]   Design and construction of a realistic digital brain phantom [J].
Collins, DL ;
Zijdenbos, AP ;
Kollokian, V ;
Sled, JG ;
Kabani, NJ ;
Holmes, CJ ;
Evans, AC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :463-468
[5]  
Kwan RKS, 1996, LECT NOTES COMPUT SC, V1131, P135, DOI 10.1007/BFb0046947
[6]  
Lavallee S, 1996, COMPUTER INTEGRATED, P77
[7]  
Maes A, 1998, THESIS ESAT PSI KU L
[8]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198
[9]  
Maintz J B, 1998, Med Image Anal, V2, P1, DOI 10.1016/S1361-8415(01)80026-8
[10]   Registration of head volume images using implantable fiducial markers [J].
Maurer, CR ;
Fitzpatrick, JM ;
Wang, MY ;
Galloway, RL ;
Maciunas, RJ ;
Allen, GS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) :447-462