Role of hydrogen tanks in the life cycle assessment of fuel cell-based auxiliary power units

被引:47
作者
Agostini, Alessandro [1 ,2 ]
Belmonte, Nadia [3 ,4 ]
Masala, Alessio [3 ,4 ]
Hu, Jianjiang [5 ]
Rizzi, Paola [3 ,4 ]
Fichtner, Maximilian [5 ]
Moretto, Pietro [6 ]
Luetto, Carlo [7 ]
Sgroi, Mauro [8 ]
Baricco, Marcello [3 ,4 ]
机构
[1] ENEA, Italian Natl Agcy New Technol Energy & Environm, Via Anguillarese 301, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dept Sustainable Crop Prod, I-29122 Piacenza, Italy
[3] Univ Turin, Dept Chem, Via P Giurla 7, I-10125 Turin, Italy
[4] Univ Turin, NIS, Via P Giurla 7, I-10125 Turin, Italy
[5] Karlsruhe Inst Technol, Inst Nanotechnol, D-76021 Karlsruhe, Germany
[6] European Commiss, Joint Res Ctr, Inst Energy & Transport, Sustainable Transport Unit, Westerchtinweg 3, NL-1755 LE Petten, Netherlands
[7] Tecnodelta SrL, Via F Parigi 5-H, I-10034 Chivasso, Italy
[8] Ctr Ric FIAT, Grp Mat Labs, Str Torino 50, I-10043 Orbassano, Italy
关键词
Auxiliary Power Unit; Fuel cell; Solid-state hydrogen storage; Life Cycle Assessment; SYSTEM; VEHICLES; STORAGE; SUSTAINABILITY; PERFORMANCE; STABILITY;
D O I
10.1016/j.apenergy.2018.01.095
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the framework of the European project SSH2S, a solid-state hydrogen storage tank - fuel cell system was demonstrated as Auxiliary Power Unit (APU) for a light duty vehicle. In this work, we have assessed the environmental impacts and the costs of the system developed. Following an eco-design approach, we have identified the processes mostly contributing to them and we have suggested possible improvements. By performing a Life Cycle Assessment (LCA), we found that, when the electricity consumption for hydrogen gas compression is included into the analysis, a solid-state hydrogen storage tank has similar greenhouse gas emissions and primary energy demand than those of type III and IV tanks. However, the resources depletion is higher for the solid-state system, even though the inclusions of the end of life of the APU and the recycling of the materials may result in different conclusions. The costs of an APU equipped with a solid-state hydrogen storage tank are significantly higher, about 1.5-2 times the systems based on type III and IV tanks. However, mature technologies are compared with a prototype, which has much room for optimization. To improve both the environmental and economic performances of the APU, a reduction of structural materials for both the solid-state hydrogen tank and Balance of Plant is recommended.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 58 条
[2]   Comparative life cycle assessment of hydrogen fuel cell passenger vehicles in different Canadian provinces [J].
Ahmadi, Pouria ;
Kjeang, Erik .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (38) :12905-12917
[3]  
Althaus HJ, 2007, 8 EC, P581
[4]  
[Anonymous], 2010, INT REFERENCE LIFE C, DOI DOI 10.2788/38479
[5]  
[Anonymous], COMMUNICATION
[6]  
[Anonymous], 2011, INT REFERENCE LIFE C, V1st
[7]  
[Anonymous], 2006, 14044 ISO
[8]  
[Anonymous], 2003, Mater. Today, DOI [10.1016/S1369-7021(03)00922-2, DOI 10.1016/S1369-7021(03)00922-2]
[9]  
[Anonymous], 2006, 140402006 EN ISO
[10]  
[Anonymous], 2013, CLIM CHANG