Local tolerance of subcutaneous injections

被引:35
作者
Fransson, J [1 ]
EspanderJansson, A [1 ]
机构
[1] UNIV UPPSALA,FAC PHARM,DEPT PHARMACEUT,S-75123 UPPSALA,SWEDEN
关键词
D O I
10.1111/j.2042-7158.1996.tb05892.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Human insulin-like growth factor I (hIGF-I) has several possible clinical applications. Because subcutaneous administration of the drug can cause pain, local tolerance to injection of different formulations with or without hIGF-I has been investigated in man using isotonic saline solution as reference. The formulations, made isotonic with NaCl, ranged in pH from 6 to 7 with phosphate buffer concentrations of 5 to 50 mM. The local tolerance after injection was assessed as injection pain on a visual analogue scale, pain duration and local tolerance (redness, paleness and oedema). The discomfort at the injection site was lowest with 10 mM phosphate, pH 7. Injection of buffer at pH 6 (50 mM phosphate) caused significantly more pain than using 10 mM phosphate, whereas the pain at pH 6 using 10 mM phosphate did not differ significantly from that experienced on injection of the solution at pH 7 using either 10 or 50 mM phosphate, hIGF-I itself did not seem to cause pain. We concluded that for subcutaneous injections at non-physiological pH, the buffer strength should be kept as low as possible to avoid pain upon injection. We also hypothesize that when a non-physiological pH must be used for stability reasons, a lower buffer strength enables more rapid normalization of the pH at the injection site.
引用
收藏
页码:1012 / 1015
页数:4
相关论文
共 16 条
[1]  
BANOS JE, 1989, METHOD FIND EXP CLIN, V11, P123
[2]   REDUCTION OF PAIN AND LOCAL COMPLICATIONS WHEN BUFFERED LIDOCAINE SOLUTION IS USED AS A LOCAL-ANESTHETIC IN CONJUNCTION WITH HYPERTHERMIA TREATMENTS - RESULTS OF A RANDOMIZED TRIAL [J].
BARNETT, TA ;
KAPP, DS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (03) :585-591
[3]  
COLEY RM, 1987, CLIN PHARMACY, V6, P725
[4]  
DOENICKE A, 1992, ANESTH ANALG, V75, P431
[5]  
Flynn G L, 1980, J Parenter Drug Assoc, V34, P139
[6]  
FRANSSON J, 1994, Patent No. 15584
[7]  
FRENKEN LAM, 1994, NEPHROL DIAL TRANSPL, V9, P1295
[8]   IDENTIFICATION OF THE COMPONENT PART IN AN EPOETIN ALFA PREPARATION THAT CAUSES PAIN AFTER SUBCUTANEOUS INJECTION [J].
FRENKEN, LAM ;
VANLIER, HJJ ;
JORDANS, JGM ;
LEUNISSEN, KML ;
VANLEUSEN, R ;
VERSTAPPEN, VMC ;
KOENE, RAP .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 22 (04) :553-556
[9]  
GAZZANIGA GM, 1993, INT SURG, V78, P271
[10]  
Guyton AC, 1991, TXB MED PHYSL