Anodic stripping voltammetry at in situ bismuth-plated carbon and gold microdisc electrodes in variable electrolyte content unstirred solutions

被引:63
作者
Baldrianova, L.
Svancara, I.
Economou, A.
Sotiropoulos, S. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Thessaloniki 54124, Greece
[2] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
关键词
bismuth film electrodes; microelectrodes; carbon fibre electrodes; gold disc electrodes; anodic stripping voltammetry;
D O I
10.1016/j.aca.2006.07.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon and gold microdisc electrodes (30 and 10 mu m, respectively) have been tested as substrates for in situ bismuth film plating from unstirred solutions of variable acetate buffer content and were subsequently used in the anodic stripping voltammetry determination of Pb(II) and Cd(II) ions. The effects of Bi(III) concentration, analyte accumulation time, stirring as well as supporting electrolyte content have been studied. Under optimal conditions good voltammetric responses were obtained by means of square wave anodic stripping voltammetry in unstirred analyte solutions of 5 x 10(-8) to 10(-6) M, even in the absence of added buffer. In an indicative application, Pb(II) ion levels were determined in tap water using bismuth-plated carbon microdisc electrodes. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 1985, STANDARD POTENTIALS
[2]   Anodic stripping voltammetry at bismuth-coated and uncoated carbon microdisk electrodes: Application to trace metals analysis in food samples [J].
Baldo, MA ;
Daniele, S .
ANALYTICAL LETTERS, 2004, 37 (05) :995-1011
[3]   Bismuth-film electrodes: recent developments and potentialities for electroanalysis [J].
Economou, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :334-340
[4]  
Feil Robert, MUTATION REFUNDAME, V600, P46, DOI [10.1016/j.mrfmmm.2006.05.029, DOI 10.1016/J.MRFMMM.2006.05.029, DOI 10.1016/J.ELECTACTA.2006.05.029]
[5]  
GUSHMAN MR, 1981, ANAL CHIM ACTA, V130, P323
[6]   A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry [J].
Hocevar, SB ;
Ogorevc, B ;
Wang, J ;
Pihlar, B .
ELECTROANALYSIS, 2002, 14 (24) :1707-1712
[7]   Ex situ preparation of bismuth film microelectrode for use in electrochemical stripping microanalysis [J].
Hutton, EA ;
Hocevar, SB ;
Ogorevc, M .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :285-292
[8]   A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair [J].
Kefala, G ;
Economou, A ;
Voulgaropoulos, A ;
Sofoniou, M .
TALANTA, 2003, 61 (05) :603-610
[9]   MICROELECTRODES FOR ANODIC-STRIPPING VOLTAMMETRY PREPARED BY HEAT SEALING THIN FIBERS OR WIRES IN A POLYPROPYLENE MATRIX [J].
NYHOLM, L ;
WIKMARK, G .
ANALYTICA CHIMICA ACTA, 1992, 257 (01) :7-13
[10]  
OSTERYOUNG J, 1991, NATO ADV SCI I E-APP, V197, P139