Wall Shear Stress in Intracranial Self-Expanding Stents Studied Using Ultra-High-Resolution 3D Reconstructions

被引:13
作者
Benndorf, G. [1 ]
Ionescu, M. [2 ]
Alvarado, M. V. y [3 ]
Hipp, J. [1 ]
Metcalfe, R. [2 ]
机构
[1] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[2] Univ Houston, Dept Mech Engn, Houston, TX USA
[3] Methodist Hosp, Res Inst, Houston, TX 77030 USA
关键词
COMPUTATIONAL FLUID-DYNAMICS; NEOINTIMAL HYPERPLASIA; CEREBRAL ANEURYSMS; ANGIOGRAPHIC CT; BLOOD-FLOW; IMPLANTATION; HEMODYNAMICS; STENOSIS; MODELS;
D O I
10.3174/ajnr.A1396
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Imaging of intracranial stents is constrained by resolution limits of current clinical imaging techniques providing insufficient visualization of deployment details and impeding its use for computational hemodynamic (CHD) simulations. The purpose of our study was to evaluate whether ultra-high-resolution MicroCT scans can illuminate detailed aspects of realistic in vitro stent deployment and serve as a reliable basis for CHD simulations of blood flow through self-expanding intracranial stents. MATERIALS AND METHODS: A Neuroform Treo (NF) stent and an Enterprise (ENT) stent were deployed in identical straight polytetrafluoroethylene tubes filled with contrast agent. MicroCT scans were obtained at a spatial resolution of 14 Am and used for ultra-high-resolution 3D reconstructions. CHD simulations were performed, with particular emphasis on local flow behavior near the wall and struts. Flow differences between the geometrically different stents were studied, RESULTS: MicroCT data revealed strut prolapse near the markers for the closed-cell design (ENT) stent and at some of the unconnected vertices of the open-cell design (NF) stent, which also showed some misalignments. CHD simulations showed that reverse wall shear stress occurred near some of the strut vertices and markers for the NF but only near the markers for the ENT. CONCLUSIONS: This work demonstrates the feasibility of ultra-high-resolution MicroCT imaging in elucidating important details of intracranial stent deployment as a basis for accurate CHD simulations and in enabling a structural and hemodynamic study of realistically deployed stents with different geometry and design.
引用
收藏
页码:479 / 486
页数:8
相关论文
共 38 条
[1]  
ALVARADO MVY, NEURORADIOL IN PRESS
[2]   Computational approach to estimating the effects of blood properties on changes in intra-stent flow [J].
Benard, Nicolas ;
Perrault, Robert ;
Coisne, Damien .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (08) :1259-1271
[3]  
Benndorf G, 2005, AM J NEURORADIOL, V26, P1813
[4]   Angiographic computed tomography for imaging of underdeployed intracranial stent [J].
Benndorf, Goetz ;
Klucznik, Richard P. ;
Strother, Charles M. .
CIRCULATION, 2006, 114 (12) :E499-E500
[5]  
BENNDORFG, 2006, NEUROSURGERY S, V58
[6]   Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[7]   Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting [J].
Buhk, Jan-Hendrik ;
Lingor, Paul ;
Knauth, Michael .
NEURORADIOLOGY, 2008, 50 (04) :349-354
[8]  
Cademartiri Filippo, 2007, Acta Biomed, V78, P6
[9]   The contribution of "mechanical" problems to in-stent restenosis: An intravascular ultrasonographic analysis of 1090 consecutive in-stent restenosis lesions [J].
Castagna, MT ;
Mintz, GS ;
Leiboff, BO ;
Ahmed, JM ;
Mehran, R ;
Satler, LF ;
Kent, KM ;
Pichard, AD ;
Weissman, NJ .
AMERICAN HEART JOURNAL, 2001, 142 (06) :970-974
[10]  
Doerfler A, 2005, AM J NEURORADIOL, V26, P862