Amperometric enzyme electrode for the determination of urine oxalate

被引:37
作者
Reddy, SM
Higson, SP
Vadgama, PM
机构
[1] UNIV MANCHESTER, HOPE HOSP, CLIN BIOCHEM SECT, SALFORD M6 8HD, LANCS, ENGLAND
[2] MANCHESTER METROPOLITAN UNIV, DEPT CHEM, MANCHESTER M1 5GD, LANCS, ENGLAND
关键词
amperometry; enzymatic methods; urine oxalate;
D O I
10.1016/S0003-2670(96)00611-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzyme electrode has been developed for the simplified determination of oxalate in human urine. Oxalate oxidase has been co-immobilised with bovine serum albumin (BSA) using glutaraldehyde between polycarbonate or haemodialysis external membranes and an internal cellulose acetate membrane to form a classical oxidase enzyme laminate construction. The underlying cellulose acetate permselective barrier confers the required selectivity for H2O2 over the interferent constituents of urine. Prior dilution and acidification of urine samples has enabled optimisation of enzyme activity and therefore electrode response characteristics for low level oxalate assay. Sequestering of singly and doubly charged cations in urine by ethylenediaminetetraacetic acid (EDTA) has ensured release of bound oxalate, so permitting near total (>98%) determination of urinary oxalate. An outer substrate diffusion Limiting membrane has proved critical to an electrode linear response within the clinical concentration range. Determination of human urinary oxalate in the concentration range 2-200 mu M in diluted urine (corresponding to 80-800 mu M oxalate in undiluted urine) has been possible. Results correlate well (r(2)=0.971; y=1.11x+4.20; n=20) with standard spectrophotometric determinations (x) performed within a hospital laboratory.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 33 条
[1]  
AMINI MAS, 1989, ANAL LETT, V22, P43
[2]   URINARY THIOCYANATE APPEARS TO BE A POWERFUL INHIBITOR OF OXALATE OXIDASE [J].
AMINI, MAS ;
VALLON, JJ ;
LARTILLOT, S .
ANALYTICA CHIMICA ACTA, 1991, 245 (01) :129-132
[3]   KINETIC EFFECTS OF OXALATE ON LIVER AND ERYTHROCYTE PYRUVATE KINASES [J].
BUC, H ;
DEMAUGRE, F ;
LEROUX, JP .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1978, 85 (02) :774-779
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   OXALATE-SENSING ENZYME ELECTRODE [J].
CLARK, LC ;
NOYES, LK ;
GROOMS, TA ;
MOORE, PE .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 434 (DEC) :512-514
[6]   MASS-TRANSPORT THROUGH POLYMERIC MEMBRANES [J].
COLLINS, MC ;
RAMIREZ, WF .
JOURNAL OF PHYSICAL CHEMISTRY, 1979, 83 (17) :2294-2301
[7]  
COSTELLO J, 1976, J LAB CLIN MED, V87, P903
[8]   FABRICATION OF A FIBER-OPTIC-BASED ELECTROCHEMILUMINESCENCE SENSOR AND ITS APPLICATION TO THE DETERMINATION OF OXALATE [J].
EGASHIRA, N ;
KUMASAKO, H ;
OHGA, K .
ANALYTICAL SCIENCES, 1990, 6 (06) :903-904
[9]   UREA AND OXALATE INHIBITION OF SERUM LACTATE DEHYDROGENASE [J].
EMERSON, PM ;
WILKINSON, JH .
JOURNAL OF CLINICAL PATHOLOGY, 1965, 18 (06) :803-+
[10]   WATER STATE OF CUPROPHAN (HEMODIALYSIS MEMBRANE) [J].
FILHO, GR ;
BUENO, WA .
JOURNAL OF MEMBRANE SCIENCE, 1992, 74 (1-2) :19-27