Electrochemical determination of Cephalothin antibiotic by adsorptive stripping voltammetric technique

被引:31
作者
Al-ghamdi, AH [1 ]
Al-Shadokhy, MA [1 ]
Al-Warthan, AA [1 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11451, Saudi Arabia
关键词
adsorptive stripping voltammetry; cephalothin; cephalosporin antibiotics; urine; serum;
D O I
10.1016/j.jpba.2004.02.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and reliable stripping voltammetric method was developed to determine Cephalothin antibiotic drug. This method is based on the adsorptive accumulation of the drug at a hanging mercury drop electrode and then a negative sweep was initiated, which yield a well defined cathodic peak at -625 mV versus Ag/AgCl reference electrode. To achieve high sensitivity, various experimental and instrumental variables were investigated such as supporting electrolyte, pH, accumulation time and potential, drug concentration, scan rate, convection rate and working electrode area. The monitored adsorptive current was directly proportional to the concentration of Cephalothin and it shows a linear response in the range from 4 x 10(-7) to 1.2 x 10(-6) mol l(-1) (correlation coefficient = 0.9995) and the detection limit (S/N = 3) is 3.3 x 10(-9) mol l(-1) at an accumulation time of 3 min. The developed AdSV procedure shows a good reproducibility, the relative standard deviation R.S.D.% (n = 10) at a concentration level of 5 x 10(-7) mol l(-1) was 0.94%. Possible interferences by other pharmaceutical drugs and surfactants have been also evaluated. The applicability of this approach was illustrated by the determination of Cephalothin in pharmaceutical preparation and biological fluids such as serum and urine. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1001 / 1009
页数:9
相关论文
共 29 条
[1]   SELECTIVE SPECTROPHOTOMETRIC DETERMINATION OF SOME CEPHALOSPORINS IN PHARMACEUTICAL FORMULATIONS [J].
ABDALLA, MA .
ANALYTICAL LETTERS, 1991, 24 (01) :55-67
[2]   Applications of adsorptive stripping voltammetry for the trace analysis of metals, pharmaceuticals and biomolecules [J].
Abu Zuhri A.Z. ;
Voelter W. .
Fresenius' Journal of Analytical Chemistry, 1998, 360 (1) :1-9
[3]  
Alghamdi A. H., 2002, J SAUDI CHEM SOC, V6, P185
[4]  
Brainina K.H., 1993, ELECTROANALYTICAL ST, P71
[5]   Stripping voltammetry in environmental and food analysis [J].
Brainina, KZ ;
Malakhova, NA ;
Stozhko, NY .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04) :307-325
[6]   Determination of unbound cephalothin in rat blood by on-line microdialysis and microbore liquid chromatography [J].
Chang, YL ;
Chen, YF ;
Chen, CF ;
Tsai, TH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (01) :125-130
[7]   POTENTIOMETRIC DETERMINATION OF CEPHALOTHIN [J].
DUMKIEWICZ, R .
ANALYST, 1989, 114 (01) :21-24
[8]  
FATMA IS, 1985, ANALYST, V110, P111
[9]   DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF CEPHALOSPORINS AND THEIR DEGRADATION PRODUCTS [J].
FOGG, AG ;
FAYAD, NM ;
BURGESS, C ;
MCGLYNN, A .
ANALYTICA CHIMICA ACTA, 1979, 108 (JUL) :205-211
[10]  
GUTIERREZ NP, 1999, BIOMED CHROMATOGR, V13, P105