Dose escalating safety study of a new oral direct thrombin inhibitor, dabigatran etexilate, in patients undergoing total hip replacement:: BISTRO I

被引:166
作者
Eriksson, BI [1 ]
Dahl, OE
Ahnfelt, L
Kälebo, P
Stangier, J
Nehmiz, G
Hermansson, K
Kohlbrenner, V
机构
[1] Sahlgrens Univ Hosp, Orthopaed Dept, Bologna, Italy
[2] Buskerud Cent Hosp, Drammen, Norway
[3] Boehringer Ingelheim GmbH & Co KG, Biberach, Germany
[4] Boehringer Ingelheim GmbH & Co KG, Stockholm, Sweden
[5] Boehringer Ingelheim GmbH & Co KG, Ridgefield, CT USA
关键词
dabigatran etexilate; deep vein thrombosis; direct; thrombin inhibitor; total hip replacement;
D O I
10.1111/j.1538-7836.2004.00890.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dabigatran etexilate (BIBR 1048) is an oral direct thrombin inhibitor undergoing evaluation for the prevention of venous thromboembolism (VTE) following total hip replacement. Following oral administration, dabigatran etexilate is rapidly converted to its active form dabigatran (BIBR 953 ZW). Objectives: To determine the safe therapeutic range of dabigatran etexilate following total hip replacement. Methods: In a multicenter, open-label, dose-escalating study, 314 patients received oral doses of dabigatran etexilate (12.5, 25, 50, 100, 150, 200 and 300 mg twice daily or 150 and 300 mg once daily) administered 4-8 h after surgery, for 6-10 days. Dose escalation was based on clinical and pharmacokinetic data. The primary safety outcome was major bleeding. The primary efficacy outcome included venographic deep vein thrombosis (DVT), symptomatic DVT and pulmonary embolism, during the treatment period. Results: No major bleeding event was observed in any group, but two patients at the highest dose (300 mg twice daily) suffered bleeding from multiple sites associated with reduced renal clearance and prolonged pharmacodynamic (PD) parameters. A dose-response was demonstrated for minor bleeding events. Of the 289 treated patients, 225 patients had evaluable venograms. The overall incidence of DVT was 12.4% (28/225 patients). There was no consistent relationship between the dose and incidence of DVT, the highest incidence in any group being 20.8% (5/24 patients). The lowest dose (12.5 mg twice daily) showed a high rate of proximal DVT [12.5% (3/24)] and no increase in PD parameters. Peak and trough plasma concentrations, area under the dabigatran plasma concentration-time curve and PD parameters also increased in proportion with the dose. Higher dabigatran plasma concentrations were associated with lower DVT rates. Approximately 20% of the patients had low plasma concentrations after the first dose suggesting further optimization of the preliminary tablet formulation is required. Conclusions: Dabigatran etexilate demonstrates an acceptable safety profile, with a therapeutic window above 12.5 mg and below 300 mg twice daily. The low number of VTE events within each treatment group indicates a satisfactory antithrombotic potential, although the study was not powered for an efficacy analysis. Additional studies are ongoing to optimize oral absorption and the efficacy/safety balance.
引用
收藏
页码:1573 / 1580
页数:8
相关论文
共 13 条
[1]   Elevation of hepatic transaminases after enoxaparin use: Case report and review of unfractionated and low-molecular-weight heparin-induced hepatotoxicity [J].
Carlson, MK ;
Gleason, PP ;
Sen, S .
PHARMACOTHERAPY, 2001, 21 (01) :108-113
[2]  
*COMM PROPR MED PR, 2000, CPMPEWP70798
[3]   Prophylaxis of venous thromboembolism with subcutaneous melagatran in total hip or total knee replacement:: Results from Phase II studies [J].
Eriksson, BI ;
Ögren, M ;
Eriksson, UG ;
Kälebo, P ;
Ahnfelt, L ;
Björkström, S ;
Sjöstedt, Å ;
Folestad, A ;
Arfwidsson, AC ;
Elvander, CS ;
Frison, L .
THROMBOSIS RESEARCH, 2002, 105 (05) :371-378
[4]  
Eriksson BI, 2002, THROMB HAEMOSTASIS, V87, P231
[5]   Prevention of venous thromboembolism [J].
Geerts, WH ;
Heit, JA ;
Clagett, GP ;
Pineo, GF ;
Colwell, CW ;
Anderson, FA ;
Wheeler, HB .
CHEST, 2001, 119 (01) :132S-175S
[6]  
Graafsma YP, 1997, THROMB HAEMOSTASIS, V78, P1189
[7]   Optimization of ascending phlebography of the leg for screening of deep vein thrombosis in thromboprophylactic trials [J].
Kalebo, P ;
Anthmyr, BA ;
Eriksson, BI ;
Zachrisson, BE .
ACTA RADIOLOGICA, 1997, 38 (02) :320-326
[8]  
Kalebo P, 1996, THROMB HAEMOSTASIS, V76, P893
[9]   PHLEBOGRAPHIC FINDINGS IN VENOUS THROMBOSIS FOLLOWING TOTAL HIP-REPLACEMENT [J].
KALEBO, P ;
ANTHMYR, BA ;
ERIKSSON, BI ;
ZACHRISSON, BE .
ACTA RADIOLOGICA, 1990, 31 (03) :259-263
[10]  
LINDBRATT S, 1995, THROMB HAEMOST, V74