Intratracheal furosemide in infants after cardiac surgery: its effects on lung mechanics and urinary output, and its levels in plasma and tracheal aspirate

被引:7
作者
Aufricht, C
Votava, F
Marx, M
Frenzel, K
Simbruner, G
机构
[1] UNIV MUNICH,DR VON HAUNERSCHEN KINDERSPITAL,KINDERKLIN,D-80337 MUNICH,GERMANY
[2] UNIV VIENNA,KINDERKLIN,A-1090 VIENNA,AUSTRIA
关键词
topical furosemide; lung mechanics; plasma levels;
D O I
10.1007/s001340050444
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Recent studies have suggested direct pulmonary effects of furosemide in asthmatics and infants with bronchopulmonary dysplasia. We tested the hypothesis that intratracheally administered furosemide also increases respiratory compliance in children after cardiac surgery, and investigated whether furosemide has a topical and/or systemic action. Study design: Prospective study with intra-individual control. In twelve infants and toddlers (age: 10 +/- 8 months, weight: 6.9 +/- 3 kg) mechanically ventilated for compromised lung mechanics after cardiac surgery 0.5 mg/kg furosemide was intratracheally administered to the lungs. Lung mechanics were serially assessed using a computerised system (Sensormedics 2600) during a 2 h control and 2 h intervention period. Urine output was measured by an indwelling bladder catheter and levels of furosemide were determined in blood and tracheal aspirates. Results: Static compliance improved within 30 min in all patients, reached a maximum of 44 (20-85) % above baseline and remained improved throughout the study (p < 0.05). An immediate, short and significant diuretic effect of intratracheally applied furosemide was observed. Furosemide levels 1 h after intervention were 795 ng/ml in the blood and 431 mu g/ml (i.e. 1000-fold higher) in the tracheal aspirate. Changes in compliance were correlated only to urine output values over the 2 h (r = 0.82, p = 0.044, n = 9) after furosemide administration. Conclusion: We conclude that intratracheally applied furosemide improves static compliance in infants and toddlers with compromised lung mechanics after cardiac surgery. We demonstrated that furosemide is absorbed from the lung and has a systemic effect within 15 min after its intratracheal instillation.
引用
收藏
页码:992 / 997
页数:6
相关论文
共 19 条
  • [1] Asthma prophylaxis agents alter the function of an airway epithelial chloride channel
    Alton, EWFW
    KingsleighSmith, DJ
    Munkonge, FM
    Smith, SN
    Lindsay, ARG
    Gruenert, DC
    Jeffery, PK
    Norris, A
    Geddes, DM
    Williams, AJ
    [J]. AMERICAN JOURNAL OF RESPIRATORY CELL AND MOLECULAR BIOLOGY, 1996, 14 (04) : 380 - 387
  • [2] ARANDA JV, 1993, J PEDIATR, V93, P507
  • [3] AUFRICHT C, 1995, PEDIATR RES, V37, pA237
  • [4] BIANCO S, 1988, LANCET, V2, P252
  • [5] THE NA-K-CL COTRANSPORTERS
    HAAS, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1994, 267 (04): : C869 - C885
  • [6] INOUE T, 1995, J NUCL MED, V36, P73
  • [7] INHALED FUROSEMIDE IS NOT EFFECTIVE IN ACUTE ASTHMA
    KARPEL, JP
    DWORKIN, F
    HAGER, D
    FELICIANO, S
    SHAPIRO, D
    POSNER, L
    LUKS, D
    [J]. CHEST, 1994, 106 (05) : 1396 - 1400
  • [8] LISTER G, 1981, CLIN CRITICAL CARE M, P67
  • [9] PHARMACOLOGY OF FUROSEMIDE IN THE PREMATURE NEWBORN-INFANT
    PETERSON, RG
    SIMMONS, MA
    RUMACK, BH
    LEVINE, RL
    BROOKS, JG
    [J]. JOURNAL OF PEDIATRICS, 1980, 97 (01) : 139 - 143
  • [10] PRABHU V, 1995, PEDIATR RES, V37, pA346