Carbon fibre plates in the treatment of femoral periprosthetic fractures

被引:26
作者
Baker, D [1 ]
Kadambande, SS [1 ]
Alderman, PM [1 ]
机构
[1] Royal Gwent Hosp, Dept Trauma & Orthopaed, Newport NPT 2VB, Gwent, Wales
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2004年 / 35卷 / 06期
关键词
carbon fibre plates; periprosthetic fractures; total hip replacement;
D O I
10.1016/j.injury.2003.10.014
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
A retrospective review of fractures occurring around the femoral component of total hip replacements was performed using patient notes and X rays. Between 1996 and 2002, 12 patients with total hip replacement had fixation of their periprosthetic femoral shaft fracture with carbon fibre plates. The mean patient age was 76 years (range 57-94). With regard to fracture type (Johansson Classification), three were Type 2 and nine were Type 3. In 11 cases the average time to union was 4 months (range 3-6). There was one non-union leading to implant failure. This was subsequently treated with a revision arthroplasty. There were no other significant complications. Although designed to fit the supracondylar region of the femur, we had no difficulty in applying the plate over the trochanteric region. Our results indicate that carbon fibre plates are effective in the management of femoral. periprosthetic fractures in the elderly and this may be related to the unique properties of the plate. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:596 / 598
页数:3
相关论文
共 11 条
[1]
The use of a carbon fiber plate for periprosthetic supracondylar femoral fractures [J].
Al-Shawi, AK ;
Smith, SP ;
Anderson, GH .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :320-324
[2]
CARBON-FIBER REINFORCED EPOXY AS A HIGH-STRENGTH, LOW MODULUS MATERIAL FOR INTERNAL-FIXATION PLATES [J].
BRADLEY, JS ;
HASTINGS, GW ;
JOHNSONNURSE, C .
BIOMATERIALS, 1980, 1 (01) :38-40
[3]
GAUTIER E, 1994, ZBL CHIR, V119, P564
[4]
THE USE OF SHORT CARBON-FIBER REINFORCED THERMOPLASTIC PLATES FOR FRACTURE FIXATION [J].
GILLETT, N ;
BROWN, SA ;
DUMBLETON, JH ;
POOL, RP .
BIOMATERIALS, 1985, 6 (02) :113-121
[5]
THE RESPONSE OF HUMAN-TISSUES TO CARBON REINFORCED EPOXY-RESIN [J].
HOWARD, CB ;
TAYTON, KJJ ;
GIBBS, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (04) :656-658
[6]
FRACTURE OF THE IPSILATERAL FEMUR IN PATIENTS WITH TOTAL HIP-REPLACEMENT [J].
JOHANSSON, JE ;
MCBROOM, R ;
BARRINGTON, TW ;
HUNTER, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1435-1442
[7]
Jukkala-Partio K, 1998, ANN CHIR GYNAECOL, V87, P229
[8]
FRACTURES OF THE DISTAL FEMUR IN THE ELDERLY TREATED WITH A CARBON-FIBER SUPRACONDYLAR PLATE [J].
PEMBERTON, DJ ;
EVANS, PD ;
GRANT, A ;
MCKIBBIN, B .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (05) :317-321
[9]
FEMORAL FRACTURE DURING NON-CEMENTED TOTAL HIP-ARTHROPLASTY [J].
SCHWARTZ, JT ;
MAYER, JG ;
ENGH, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (08) :1135-1142
[10]