The effect of pulsed electromagnetic fields on the osteointegration of hydroxyapatite implants in cancellous bone:: a morphologic and microstructural in vivo study

被引:61
作者
Fini, M
Cadossi, R
Canè, V
Cavani, F
Giavaresi, G
Krajewski, A
Martini, L
Aldini, NN
Ravaglioli, A
Rimondini, L
Torricelli, P
Giardino, R
机构
[1] Ist Ortoped Rizzoli, Dept Expt Surg, I-40136 Bologna, Italy
[2] IGEA SRL, Modena, Italy
[3] Univ Modena, Dept Morphol & Forens Med Sci, Sect Human Anat, I-41100 Modena, Italy
[4] Irtec CNR, Inst Technol Res Ceram, Faenza, Italy
[5] Univ Milan, Dept Oral Med & Pathol, Milan, Italy
[6] Univ Bologna, Chair Surg Patholphysiol, Bologna, Italy
关键词
electromagnetic fields; osteointegration; hydroxyapatite; rabbits;
D O I
10.1016/S0736-0266(01)00158-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Effects of pulsed electromagnetic fields (PEMFs. 75 Hz. L6 mT) were investigated in 12 rabbits after placing hydroxyapatite (HA) implants in their femoral condyles. Six animals were stimulated with PEMFs, for three consecutive weeks, 6 h/day, while the remaining animals were sham-treated (Control Group). Rabbits were sacrificed at 3 and 6 weeks (after a 3-week non-stimulation period) For histomorphometric analysis and microhardness testing (at 200, 500, 1000, 2000 mum from the implant) around the implants. Histomorphometric analysis did not highlight any significant changes. On the contrary, there were statistically significant differences between the effects produced by PEMFs and Control Groups (r = 149.70, p = 0.0005) on the Affinity Index results as well as by the experimental time of 6 and 3 weeks (F = 17.12, p = 0.001) on the same results. In PEMF-stimulated animals the microhardness (HV) values measured in trabecular bone at a distance of 200 and 500 mum from the implants, were significantly higher with respect to controls. At 6 weeks HV values at the bone implant interface in PEMF-stimulated animals were not significantly different with respect to normal bone, while they remained significantly loader in control animals, Both morphological and structural results demonstrated a positive therapeutic effect of PEMFs in accelerating HA osteointegration in trabecular bone. (C) 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:756 / 763
页数:8
相关论文
共 46 条
[1]   STIMULATION OF EXPERIMENTAL ENDOCHONDRAL OSSIFICATION BY LOW-ENERGY PULSING ELECTROMAGNETIC-FIELDS [J].
AARON, RK ;
CIOMBOR, DM ;
JOLLY, G .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (02) :227-233
[2]   ACCELERATION OF FRACTURE REPAIR BY ELECTROMAGNETIC-FIELDS - SURGICALLY NONINVASIVE METHOD [J].
BASSETT, CAL ;
PAWLUK, RJ ;
PILLA, AA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1974, 238 (OCT11) :242-262
[3]   LONG-TERM PULSED ELECTROMAGNETIC-FIELD (PEMF) RESULTS IN CONGENITAL PSEUDOARTHROSIS [J].
BASSETT, CAL ;
SCHINKASCANI, M .
CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (03) :216-220
[4]   Factors in implant integration failure after bone grafting - An osteometric and endocrinologic matched analysis [J].
Blomqvist, JE ;
Alberius, P ;
Isaksson, S ;
Linde, A ;
Hansson, BG .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (01) :63-68
[5]  
BORSALINO G, 1988, CLIN ORTHOP RELAT R, V237, P256
[6]   DIRECT-CURRENT INFLUENCE ON BONE-FORMATION IN TITANIUM IMPLANTS [J].
BUCH, F ;
ALBREKTSSON, T ;
HERBST, E .
BIOMATERIALS, 1984, 5 (06) :341-346
[7]   PULSED MAGNETIC-FIELDS IMPROVE OSTEOBLAST ACTIVITY DURING THE REPAIR OF AN EXPERIMENTAL OSSEOUS DEFECT [J].
CANE, V ;
BOTTI, P ;
SOANA, S .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (05) :664-670
[8]   ELECTROMAGNETIC STIMULATION OF BONE REPAIR - A HISTOMORPHOMETRIC STUDY [J].
CANE, V ;
BOTTI, P ;
FARNETI, D ;
SOANA, S .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (06) :908-917
[9]  
CAPANNA R, 1994, CLIN ORTHOP RELAT R, P213
[10]   Hydroxyapatite in total hip arthroplasty -: Clinical results and critical issues [J].
Capello, WN ;
D 'Antonio, JA ;
Manley, MT ;
Feinberg, JR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) :200-211