Comparative measurements of multicomponent phospholipid mixtures by electrospray mass spectroscopy: relating ion intensity to concentration

被引:37
作者
Zacarias, A [1 ]
Bolanowski, D [1 ]
Bhatnagar, A [1 ]
机构
[1] Univ Louisville, Dept Med, Div Cardiol, Louisville, KY 40202 USA
基金
美国国家卫生研究院;
关键词
electrospray; phospholipid; mass spectrometry; quantitative analysis;
D O I
10.1016/S0003-2697(02)00209-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray mass spectrometry allows direct identification and sensitive detection of multiple phospholipids in non-derivatized cell extracts. However, quantitative analyses are not straightforward, and are confounded by analyte and mass discrimination effects, and non-linear dependence of the ion intensity on concentration. This non-linearity is particularly severe in the negative mode and precludes even comparative measurements of anion concentrations. Herein, we report a general method for relating negative electrospray ion intensity to concentration when analyzing multicomponent phospholipid samples. In this method, the intensity of individual ions is measured at several different concentrations of the total mixture and the slope (n(E)) of the double log plot of sample concentration vs. intensity for each analyte is determined. The nE is then used to map intensity data to a quantity proportional to concentration for each analyte. The method allows facile and accurate comparison of negative spectra of complex mixtures containing structurally different anions. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 35 条
[1]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - QUANTITATIVE ASPECTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :649-654
[2]   Direct quantitative analysis of lysophosphatidic acid molecular species by stable isotope dilution electrospray ionization liquid chromatography-mass spectrometry [J].
Baker, DL ;
Desiderio, DM ;
Miller, DD ;
Tolley, B ;
Tigyi, GJ .
ANALYTICAL BIOCHEMISTRY, 2001, 292 (02) :287-295
[3]  
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[4]   Quantitative analysis of biological membrane lipids at the low picomole level by nano-electrospray ionization tandem mass spectrometry [J].
Brugger, B ;
Erben, G ;
Sandhoff, R ;
Wieland, FT ;
Lehmann, WD .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (06) :2339-2344
[5]   Plasmalogen-derived lysolipid induces a depolarizing cation current in rabbit ventricular myocytes [J].
Caldwell, RA ;
Baumgarten, CM .
CIRCULATION RESEARCH, 1998, 83 (05) :533-540
[6]   Relating electrospray ionization response to nonpolar character of small peptides [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2717-2723
[7]   THE CURRENT EMITTED BY HIGHLY CONDUCTING TAYLOR CONES [J].
DELAMORA, JF ;
LOSCERTALES, IG .
JOURNAL OF FLUID MECHANICS, 1994, 260 :155-184
[8]   Electrospray/tandem mass spectrometry for quantitative analysis of lipid remodeling in essential fatty acid deficient mice [J].
Duffin, K ;
Obukowicz, M ;
Raz, A ;
Shieh, JJ .
ANALYTICAL BIOCHEMISTRY, 2000, 279 (02) :179-188
[9]   A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[10]   Quantitative analysis of phospholipids in functionally important membrane domains from RBL-2H3 mast cells using tandem high-resolution mass spectrometry [J].
Fridriksson, EK ;
Shipkova, PA ;
Sheets, ED ;
Holowka, D ;
Baird, B ;
McLafferty, FW .
BIOCHEMISTRY, 1999, 38 (25) :8056-8063