A multicenter US experience with EUS-guided fine-needle aspiration using the Olympus GF-UM30P echoendoscope: safety and effectiveness

被引:21
作者
Sahai, AV
Schembre, D
Stevens, PD
Chak, A
Isenberg, G
Lightdale, CJ
Sivak, MV
Hawes, RH
机构
[1] Med Univ S Carolina, Ctr Digest Dis, Charleston, SC 29425 USA
[2] Columbia Presbyterian Med Ctr, New York, NY 10032 USA
[3] Case Western Reserve Univ, Cleveland, OH 44106 USA
关键词
D O I
10.1016/S0016-5107(99)70160-4
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The aim of this study was to determine the safety, efficacy, and accuracy of endoscopic ultrasound (EUS)-guided fine-needle aspiration using the GF-UM30P echoendoscope. Methods: GFUM30P-guided EUS-guided fine-needle aspiration results from 3 EUS referral centers were prospectively recorded. Successful sampling required that the needle tip be seen within the lesion on at least 1 pass. Aspirates were considered adequate if they were diagnostic for cancer, contained suspicious or atypical cells, or were adequately cellular for interpretation but nondiagnostic. Results: EUS-guided fine-needle aspiration was attempted on 162 lesions in 152 patients with no complications. Sampling was successful in 150 of 162 (93%) attempts (mean lesion size 2.5 +/- 1.2 cm (range 0.7 to 6.0 cm). Aspirates were adequately cellular in 138 of 162 (85%) attempts (43% diagnostic, 15% suspicious and/or atypical cells, 27% adequate cellularity but nondiagnostic). Sampling failed in 12 of 162 (7%) attempts. Ten of 12 (83%) failures and 11 of 12 (92%) inadequate aspirates occurred when lesions measured less than 2 cm. The sensitivity for malignancy was 93% if only successfully sampled lesions with surgically confirmed negative results were included. However, it was 68% if all attempts were included and when unconfirmed high/moderate suspicion negative results were counted as false negatives and low suspicion negative results as true negatives. Conclusions: The GF-UM30P may be clinically useful for EUS-guided line-needle aspiration if a curved linear array instrument Is unavailable.
引用
收藏
页码:792 / 796
页数:5
相关论文
共 10 条
[1]   EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope [J].
Binmoeller, KF ;
Brand, B ;
Thul, R ;
Rathod, V ;
Soehendra, N .
GASTROINTESTINAL ENDOSCOPY, 1998, 47 (05) :335-340
[2]  
CHANG KJ, 1996, GASTROINTEST ENDOSC, V43, P417
[3]   ASSESSMENT OF DIAGNOSTIC TECHNOLOGIES - METHODOLOGY FOR UNBIASED ESTIMATION FROM SAMPLES OF SELECTIVELY VERIFIED PATIENTS [J].
GREENES, RA ;
BEGG, CB .
INVESTIGATIVE RADIOLOGY, 1985, 20 (07) :751-756
[4]   Endoscopic ultrasound-guided fine-needle aspiration biopsy using linear array and radial scanning endosonography [J].
Gress, FG ;
Hawes, RH ;
Savides, TJ ;
Ikenberry, SO ;
Lehman, GA .
GASTROINTESTINAL ENDOSCOPY, 1997, 45 (03) :243-250
[5]   Fine-needle aspiration of posterior mediastinal lesions guided by radial scanning endosonography [J].
Ikenberry, S ;
Gress, F ;
Savides, T ;
Hawes, R .
GASTROINTESTINAL ENDOSCOPY, 1996, 43 (06) :605-610
[6]   USERS GUIDES TO THE MEDICAL LITERATURE .3. HOW TO USE AN ARTICLE ABOUT A DIAGNOSTIC-TEST .B. WHAT ARE THE RESULTS AND WILL THEY HELP ME IN CARING FOR MY PATIENTS [J].
JAESCHKE, R ;
GUYATT, GH ;
SACKETT, DL ;
GUYATT, G ;
BASS, E ;
BRILLEDWARDS, P ;
BROWMAN, G ;
COOK, D ;
FARKOUH, M ;
GERSTEIN, H ;
HAYNES, B ;
HAYWARD, R ;
HOLBROOK, A ;
JUNIPER, E ;
LEE, H ;
LEVINE, M ;
MOYER, V ;
NISHIKAWA, J ;
OXMAN, A ;
PATEL, A ;
PHILBRICK, J ;
RICHARDSON, WS ;
SAUVE, S ;
SACKETT, D ;
SINCLAIR, J ;
TROUT, KS ;
TUGWELL, P ;
TUNIS, S ;
WALTER, S ;
WILSON, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (09) :703-707
[7]   Indications, contraindications, and complications of endoscopic ultrasonography [J].
Lightdale, CJ .
GASTROINTESTINAL ENDOSCOPY, 1996, 43 (02) :S15-S19
[8]   Endoscopic ultrasound with fine-needle aspiration in the diagnosis and staging of lung cancer [J].
Silvestri, GA ;
Hoffman, BJ ;
Bhutani, MS ;
Hawes, RH ;
Coppage, L ;
SandersCliette, A ;
Reed, CE .
ANNALS OF THORACIC SURGERY, 1996, 61 (05) :1441-1445
[9]  
Soetikno RM, 1998, GASTROINTEST ENDOSC, V47, pAB39
[10]   Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment [J].
Wiersema, MJ ;
Vilmann, P ;
Giovannini, M ;
Chang, KJ ;
Wiersema, LM .
GASTROENTEROLOGY, 1997, 112 (04) :1087-1095