Development of a unique phantom to assess the geometric accuracy of magnetic resonance imaging for stereotactic localization

被引:43
作者
Orth, RC
Sinha, P
Madsen, EL
Frank, G
Korosec, FR
Mackie, TR
Mehta, MP
机构
[1] Univ Wisconsin, Dept Human Oncol, Madison, WI USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
computed tomography; magnetic resonance imaging; phantom; spatial accuracy; stereotactic radiosurgery;
D O I
10.1097/00006123-199912000-00030
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To test the spatial accuracy of coordinates generated from magnetic resonance imaging (MRI) scans, using the Brown-Roberts-Wells head frame and localizer system (Radionics, Inc., Burlington, MA). METHODS: An anthropomorphic head phantom, consisting of a two-dimensional lattice of acrylic spheres (4-mm diameter) spaced 10 mm apart and embedded in a brain tissue-mimicking gelatin-agar gel, was constructed. The intersphere distances for the target lattice positions in MRI and computed tomographic scan sets were compared. The data sets were fused, and differences in fiducial marker and intraphantom target positions were measured. RESULTS: Intersphere distances were identical for the MRI and computed tomographic scan sets (10 +/- 0.1 mm). Differences in fiducial marker positions [maximal lateral difference, 0.97 mm; mean absolute lateral difference, 0.69 +/- 0.22 mm; maximal anteroposterior (AP) difference, 1.99 mm; mean absolute AP difference, 1.29 +/- 0.67 mm] were correlated with differences in intraphantom target positions (maximal lateral difference, 0.83 mm; mean absolute lateral difference, 0.28 +/- 0.24 mm; maximal AP difference, -1.97 mm; mean absolute AP difference, 1.63 +/- 25 mm; maximal vertical difference, -0.73 mm; mean absolute vertical difference, 0.34 +/- 0.21 mm). This suggested that improper fiducial rod identification and the subsequent transformation to stereotactic coordinate space were the greatest sources of spatial uncertainty. CONCLUSION: With computed tomographic data as the standard, these differences resulted in maximal and minimal composite uncertainties of 2.06 and 1.17 mm, respectively. The measured uncertainties exceed recommended standards for radiosurgery but allow the possible use of MRI-based stereotactic treatment planning for certain intracranial lesions, if the errors are corrected using appropriate software. Clinicians must recognize that error magnitudes vary for different systems, and they should perform systematic, scheduled, institutional error analyses as part of their ongoing quality assurance processes. This phantom provides one tool For measuring such variances.
引用
收藏
页码:1423 / 1429
页数:7
相关论文
共 23 条
[1]   MAGNETIC-RESONANCE IMAGE-DIRECTED STEREOTAXIC NEUROSURGERY - USE OF IMAGE FUSION WITH COMPUTERIZED-TOMOGRAPHY TO ENHANCE SPATIAL ACCURACY [J].
ALEXANDER, E ;
KOOY, HM ;
VANHERK, M ;
SCHWARTZ, M ;
BARNES, PD ;
TARBELL, N ;
MULKERN, RV ;
HOLUPKA, EJ ;
LOEFFLER, JS .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :271-276
[2]   TISSUE-MIMICKING GELATIN AGAR GELS FOR USE IN MAGNETIC-RESONANCE IMAGING PHANTOMS [J].
BLECHINGER, JC ;
MADSEN, EL ;
FRANK, GR .
MEDICAL PHYSICS, 1988, 15 (04) :629-636
[3]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[4]   EFFECTS OF COREGISTRATION OF MR TO CT IMAGES ON MR STEREOTAXIC ACCURACY [J].
COHEN, DS ;
LUSTGARTEN, JH ;
MILLER, E ;
KHANDJI, AG ;
GOODMAN, RR .
JOURNAL OF NEUROSURGERY, 1995, 82 (05) :772-779
[5]   CLINICAL EFFICACY OF MAGNETIC-RESONANCE-IMAGING IN NEUROIMAGING [J].
KENT, DL ;
HAYNOR, DR ;
LONGSTRETH, WT ;
LARSON, EB .
ANNALS OF INTERNAL MEDICINE, 1994, 120 (10) :856-871
[6]   Magnetic resonance imaging (MRI): Considerations and applications in radiotherapy treatment planning [J].
Khoo, VS ;
Dearnaley, DP ;
Finnigan, DJ ;
Padhani, A ;
Tanner, SF ;
Leach, MO .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (01) :1-15
[7]   A COMPARISON BETWEEN MAGNETIC-RESONANCE-IMAGING AND COMPUTED-TOMOGRAPHY FOR STEREOTAXIC COORDINATE DETERMINATION [J].
KONDZIOLKA, D ;
DEMPSEY, PK ;
LUNSFORD, D ;
HEILBRUN, MP ;
KESTLE, JRW ;
DOLAN, EJ ;
KANAL, E ;
TASKER, RR .
NEUROSURGERY, 1992, 30 (03) :402-407
[8]   IMAGE FUSION FOR STEREOTAXIC RADIOTHERAPY AND RADIOSURGERY TREATMENT PLANNING [J].
KOOY, HM ;
VANHERK, M ;
BARNES, PD ;
ALEXANDER, E ;
DUNBAR, SF ;
TARBELL, NJ ;
MULKERN, RV ;
HOLUPKA, EJ ;
LOEFFLER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05) :1229-1234
[9]   CONSENSUS STATEMENT ON STEREOTAXIC RADIOSURGERY QUALITY IMPROVEMENT [J].
LARSON, DA ;
BOVA, F ;
EISERT, D ;
KLINE, R ;
LOEFFLER, J ;
LUTZ, W ;
MEHTA, M ;
PALTA, J ;
SCHEWE, K ;
SCHULTZ, C ;
SHAW, E ;
WILSON, F ;
LUNSFORD, LD ;
ALEXANDER, E ;
CHAPMAN, P ;
COFFEY, R ;
FRIEDMAN, W ;
HARSH, G ;
MACIUNAS, R ;
OLIVIER, A ;
STEINBERG, G ;
WALSH, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :527-530
[10]   VOXEL-BASED LOCALIZATION IN FRAME-BASED AND FRAMELESS STEREOTAXY AND ITS ACCURACY [J].
LEMIEUX, L ;
KITCHEN, ND ;
HUGHES, SW ;
THOMAS, DGT .
MEDICAL PHYSICS, 1994, 21 (08) :1301-1310