Ionode detection and capillary electrophoresis integrated on a polymer micro-chip

被引:9
作者
Bianchi, F [1 ]
Lee, HJ [1 ]
Girault, HH [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Electrochim, CH-1015 Lausanne, Switzerland
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2002年 / 523卷 / 1-2期
关键词
floating HV; micro-capillary electrophoresis electrochemical detection device; polymer micro-chip; micro-ionodes detector; amperometry; liquid vertical bar gel interface; on-column detection;
D O I
10.1016/S0022-0728(02)00706-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturised capillary electrophoresis system integrating amperometric ionodes for the electrochemical (EC) detection of non-redox ionic species is presented. The micro-chip comprising an injection, a separation and an amperometric ion-sensitive detector structure has been developed on a single planar polymer substrate. UV excimer laser photoablation on a poly(ethylene terephthalate) (PET) substrate allows the fabrication of the complete micro-chip in a single step and in a very short time (less than 20 min). An electrokinetic separation procedure by means of a floating high voltage (HV) Source is employed to improve the electrical decoupling between HV and EC detection. As a result, no significant distortion in the EC response is observed even for electrophoretic currents up to 140 muA. Also the floating HV prevents electrokinetic injection bias and the amount of the electrokinetically injected sample was found to be constant as a function of the injection duration, As a preliminary demonstration, a sample solution containing two non-redox organic ions can be analysed in less than a minute. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:40 / 48
页数:9
相关论文
共 39 条
[1]   Electroosmotic flow in composite microchannels and implications in microcapillary electrophoresis systems [J].
Bianchi, F ;
Wagner, F ;
Hoffmann, P ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :829-836
[2]   Finite element simulation of an electroosmotic-driven flow division at a T-junction of microscale dimensions [J].
Bianchi, F ;
Ferrigno, A ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :1987-1993
[3]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[4]   Electroosmotically induced hydraulic pumping on microchips: Differential ion transport [J].
Culbertson, CT ;
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2285-2291
[5]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO
[6]  
2-7
[7]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[8]   Counting single chromophore molecules for ultrasensitive analysis and separations on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Davis, LM ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :431-437
[9]   Square-wave voltammetry detection for capillary electrophoresis [J].
Gerhardt, GC ;
Cassidy, RM ;
Baranski, AS .
ANALYTICAL CHEMISTRY, 1998, 70 (10) :2167-2173
[10]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192