A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry

被引:40
作者
Wang, XH
Ning, RL
机构
[1] Univ Rochester, Dept Radiol, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14642 USA
[3] Eastman Kodak Co, Hlth Imaging Res Lab, Rochester, NY 14650 USA
关键词
circle-plus-arc orbit; cone-beam computerized tomography; cone-beam reconstruction algorithm; Radon transform;
D O I
10.1109/42.802759
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In cone-beam computerized tomography (CT), projections acquired with the focal spot constrained on a planar orbit cannot provide a complete set of data to reconstruct the object function exactly. There are severe distortions in the reconstructed noncentral transverse planes when the cone angle is large. In this work, a new method is proposed which can obtain a complete set of data by acquiring cone-beam projections along a circle-plus-arc orbit. A reconstruction algorithm using this circle-plus-arc orbit is developed, based on the Radon transform and Grangeat's formula. This algorithm first transforms the cone-beam projection data of an object to the first derivative od the three-dimensional (3-D) Radon transform, using Grangeat's formula, and then reconstructs the object using the inverse Radon transform. In order to reduce interpolation errors, new rebinning equations have been derived accurately, which allows one-dimensional (1-D) interpolation to be used in the rebinning process instead of 3-D interpolation, A noise-free Defrise phantom and a Poisson noise-added Shepp-Logan phantom were simulated and reconstructed for algorithm validation. The results from the computer simulation indicate that the new cone-beam data-acquisition scheme can provide a complete set of projection data and the image reconstruction algorithm can achieve exact reconstruction, Potentially, the algorithm can be applied in practice for both a standard CT gantry-based volume tomographic imaging system and a C-arm-based cone-beam tomographic imaging system, with little mechanical modification required.
引用
收藏
页码:815 / 824
页数:10
相关论文
共 26 条
[1]   3-DIMENSIONAL RECONSTRUCTION FROM CONE-BEAM DATA IN O(N-3 LOG-N) TIME [J].
AXELSSON, C ;
DANIELSSON, PE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :477-491
[2]  
CLACK R, 1991, LECT NOTES COMPUT SC, V511, P45, DOI 10.1007/BFb0033741
[3]  
DANIELSSON PE, 1992, IEEE NUCL SCI S MED
[4]   A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION [J].
DEFRISE, M ;
CLACK, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) :186-195
[5]  
Eriksson J., 1995, Proceedings of the 1995 International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, P287
[6]  
Fahrig R, 1997, AM J NEURORADIOL, V18, P1507
[7]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[8]  
GRANGEAT P, 1991, LECT NOTES MATH, V1497, P66
[9]  
Joseph P M, 1982, IEEE Trans Med Imaging, V1, P192, DOI 10.1109/TMI.1982.4307572
[10]  
KAK AC, 1987, PRINCIPLES COMPUTATI