Determination of surfactant concentration using micellar enhanced fluorescence and flow injection titration

被引:36
作者
Lucy, CA [1 ]
Tsang, JSW [1 ]
机构
[1] Univ Calgary, Dept Chem, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
titration; phosphate buffer; micelle; surfactant;
D O I
10.1016/S0039-9140(99)00238-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection titration was used for the determination of anionic, cationic, nonionic and zwitterionic surfactants. The procedure was based on the micellar-enhanced fluorescence of 1,8-anilino-naphthalene sulfonate (ANS). Samples were injected into a carrier stream of phosphate buffer and 1.0 mol 1 (-) (1) NaCl. The sample then passed through a mixing chamber which generated the exponential peak shape needed for the titration as well as diluted the sample in the carrier stream to control the pH and ionic strength of the sample. The peak width was linearly related to the logarithm of the surfactant concentration. The minimum detectable concentration was governed by the critical micelle concentration for anionic, zwitterionic and nonionic surfactants, but below the critical micelle concentration for cationic surfactants. The linear range extended for similar to 1.5 orders of magnitude. Reproducibility ranged from 12% at the lower end of the calibration range to 1.1% at higher concentrations. For SDS recoveries of 82-108% were achieved in matrices as concentrated as 1 mol 1 (- 1) in NaCl or Na2SO4. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1283 / 1289
页数:7
相关论文
共 40 条
[1]  
*ASTM, D304989 ASTM
[2]  
*ASTM, D425189 ASTM
[3]   EFFECT OF ENCAPSULATED CA2+ ON THE SURFACE-PROPERTIES OF CURVED PHOSPHATIDYLCHOLINE BILAYERS [J].
BAKAS, LS ;
DISALVO, EA .
BIOCHIMICA ET BIOPHYSICA ACTA, 1991, 1065 (02) :114-120
[4]   FLOW-REVERSAL FLOW-INJECTION ANALYSIS - ENHANCEMENT OF FLOW-INJECTION TITRATIONS [J].
CLARK, GD ;
ZABLE, J ;
RUZICKA, J ;
CHRISTIAN, GD .
TALANTA, 1991, 38 (02) :119-124
[5]   RAPID DETERMINATIONS OF COMPLEXING STABILITY-CONSTANTS BY GRADIENT FLOW-INJECTION TITRATION [J].
DACONCEICAO, AC ;
GONCALVES, MLSS ;
DOSSANTOS, MMC .
ANALYTICA CHIMICA ACTA, 1995, 302 (01) :97-102
[6]   A FLUORIMETRIC METHOD FOR THE ESTIMATION OF THE CRITICAL MICELLE CONCENTRATION OF SURFACTANTS [J].
DEVENDITTIS, E ;
PALUMBO, G ;
PARLATO, G ;
BOCCHINI, V .
ANALYTICAL BIOCHEMISTRY, 1981, 115 (02) :278-286
[7]  
Etxebarria MB, 1997, ANAL SCI, V13, P89
[8]   TRIANGLE PROGRAMMED COULOMETRIC FLOW TITRATION WITH POTENTIOMETRIC AND OPTICAL-DETECTION [J].
FEHER, Z ;
NAGY, G ;
SLEZSAK, I ;
TOTH, K ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :521-530
[9]   FIA TITRATIONS OF SULFIDE, CYSTEINE AND THIOL-CONTAINING DRUGS WITH CHEMILUMINESCENT DETECTION [J].
GARCIA, IL ;
VINAS, P ;
GIL, JAM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (11) :723-726
[10]   EXPOSURE OF HYDROPHOBIC SURFACES ON THE CHAPERONIN GROEL OLIGOMER BY PROTONATION OR MODIFICATION OF HIS-401 [J].
GIBBONS, DL ;
HOROWITZ, PM .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1995, 270 (13) :7335-7340