Remote electronic blood release system

被引:33
作者
Cox, C
Enno, A
Deveridge, S
Seldon, M
Richards, R
Martens, V
Woodford, P
机构
[1] HUNTER AREA PATHOL SERV,DIV HAEMATOL,NEWCASTLE,NSW 2298,AUSTRALIA
[2] NEW S WALES RED CROSS,BLOOD TRANSFUS SERV,HUNTER REG,NEWCASTLE,NSW,AUSTRALIA
关键词
D O I
10.1046/j.1537-2995.1997.37997454025.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The Hunter Area Pathology Service provides transfusion services to 4 metropolitan and 11 rural hospitals in Australia. To improve blood availability, conserve blood stocks, and reduce crossmatch-to-transfusion ratios, a networked electronic blood release system (EBRS) has been developed for computer crossmatching within the laboratory and al sites remote from the transfusion laboratory. It is innovative, in that nonlaboratory staffs have been trained to release computer-matched blood at remote hospitals without transfusion laboratories. STUDY DESIGN AND METHODS: The EBRS software was tested and validated according to the Australian software standards AS 3563.1 and 3563.2 (1991). Over 7000 units were released by the EBRS in a laboratory trial conducted in conjunction with the conventional immediate-spin crossmatch. A further, 12-month study was conducted within the laboratory before the staged implementation of the EBRS at the remote hospitals. RESULTS: The EBRS has resulted in 1) a 25-percent reduction in the number of units requested by the medical staff, resulting from the reduction in time needed to provide compatible blood due to the elimination of the serologic crossmatch; 2) better blood stock management (reducing outdated red cell units by 30%); and 3) significant savings in laboratory workload (savings of approximately 100 hours/month). In addition, the rapid availability of computer-crossmatched red cells in emergency situations has enhanced patient safety. CONCLUSION: The EBRS is a sale and efficient means of providing red cells within the laboratory and at remote hospitals without laboratory services.
引用
收藏
页码:960 / 964
页数:5
相关论文
共 19 条
[1]   REQUIREMENTS FOR THE COMPUTER CROSS-MATCH [J].
BUTCH, SH ;
JUDD, WJ .
TRANSFUSION, 1994, 34 (02) :187-187
[2]   ELECTRONIC VERIFICATION OF DONOR-RECIPIENT COMPATIBILITY - THE COMPUTER CROSS-MATCH [J].
BUTCH, SH ;
JUDD, WJ ;
STEINER, EA ;
STOE, M ;
OBERMAN, HA .
TRANSFUSION, 1994, 34 (02) :105-109
[3]   A novel system for providing compatible blood to patients during surgery: ''Self-service'' electronic blood banking by nursing staff [J].
Cheng, G ;
Chiu, DSM ;
Chung, ASM ;
Wong, HF ;
Chan, MWK ;
Lui, YK ;
Choy, FMF ;
Chan, JCM ;
Chan, AHC ;
Lam, ST ;
Fan, TCW .
TRANSFUSION, 1996, 36 (04) :347-350
[4]   SAFETY AND COST-CONTAINMENT DATA THAT ADVOCATE ABBREVIATED PRETRANSFUSION TESTING [J].
CORDLE, DG ;
STRAUSS, RG ;
SNYDER, EL ;
FLOSS, AM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1990, 94 (04) :428-431
[5]  
Duguid J K, 1990, Baillieres Clin Haematol, V3, P999, DOI 10.1016/S0950-3536(05)80144-1
[6]  
Georgsen J., 1995, Transfusion (Bethesda), V35, p75S
[7]   DISCREPANCIES IN REVERSE ABO TYPING DUE TO PROZONE - HOW SAFE IS THE IMMEDIATE-SPIN CROSSMATCH [J].
JUDD, WJ ;
STEINER, EA ;
ODONNELL, DB ;
OBERMAN, HA .
TRANSFUSION, 1988, 28 (04) :334-338
[8]  
JUDD WJ, 1991, TRANSFUSION, V31, P396
[9]   ARE THERE BETTER WAYS THAN THE CROSS-MATCH TO DEMONSTRATE ABO INCOMPATIBILITY [J].
JUDD, WJ .
TRANSFUSION, 1991, 31 (03) :192-194
[10]   THE SENSITIVITY AND SPECIFICITY OF THE IMMEDIATE-SPIN CROSSMATCH [J].
MEYER, EA ;
SHULMAN, IA .
TRANSFUSION, 1989, 29 (02) :99-102