A molecular rotor as viscosity sensor in aqueous colloid solutions

被引:32
作者
Akers, W [1 ]
Haidekker, MA [1 ]
机构
[1] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2004年 / 126卷 / 03期
关键词
D O I
10.1115/1.1762894
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Molecular rotors exhibit viscosity-dependent quantum yield, allowing non-mechanical determination of fluid viscosity. We analyzed fluorescence in the presence of viscosity-modulating macromolecules several orders of magnitude larger than the rotor molecule. Method of approach: Fluorescence of aqueous starch solutions with a molecular rotor in solution was related to viscosity obtained in a cone-and-plate viscometer Results: In dextran solutions, emission intensity was found to follow a power-law relationship with viscosity. Fluorescence in hydroxyerhylstarch solutions showed biexponential behavior with different exponents at viscosities above and below 1.5 mPa s. Quantum yield was generally higher in hydroxyethylstarch than in dextran solutions. The power-law relationship was used to backcalculate viscosity from intensity with an average precision of 2.2% (range of -5.5% to 5.1%). Conclusions: This study indicates that hydrophilic molecular rotors are suitable as colloid solution viscosity probes after colloid-dependent calibration.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 20 条
[1]   INVIVO RHEOLOGICAL EFFECTS OF PLASMA SUBSTITUTES [J].
DEWACHTER, P ;
LAXENAIRE, MC ;
DONNER, M ;
KURTZ, M ;
STOLTZ, JF .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1992, 11 (05) :516-525
[2]  
DEZARATE AJG, 1991, REV ESP ANESTESIOL R, V38, P90
[4]   Hematocrit, volume expander, temperature, and shear rate effects on blood viscosity [J].
Eckmann, DM ;
Bowers, S ;
Stecker, M ;
Cheung, AT .
ANESTHESIA AND ANALGESIA, 2000, 91 (03) :539-545
[5]  
FORSTER T, 1971, Z PHYS CHEM NEUE FOL, V75, P63
[6]  
FOSTER JF, 1965, STARCH CHEM TECHNOLO, P349
[7]   A novel approach to blood plasma viscosity measurement using fluorescent molecular rotors [J].
Haidekker, MA ;
Tsai, AG ;
Brady, T ;
Stevens, HY ;
Frangos, JA ;
Theodorakis, E ;
Intaglietta, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (05) :H1609-H1614
[8]   Fluid shear stress increases membrane fluidity in endothelial cells: a study with DCVJ fluorescence [J].
Haidekker, MA ;
L'Heureux, N ;
Frangos, JA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 278 (04) :H1401-H1406
[9]   Producion from sucrose of a serologically reactive polysaccharide by a sterile bacterial extract [J].
Hehre, EJ .
SCIENCE, 1941, 93 :237-238
[10]   9-(DICYANOVINYL)JULOLIDINE BINDING TO BOVINE BRAIN CALMODULIN [J].
IIO, T ;
ITAKURA, M ;
TAKAHASHI, S ;
SAWADA, S .
JOURNAL OF BIOCHEMISTRY, 1991, 109 (04) :499-502