A fully automated system for screening protein crystals for X-ray diffraction analysis has been designed and is being installed on the beamline BW6 at DORIS in Hamburg, Germany. The system includes robotic mounting of flash-frozen crystals from a storage dewar, centering and alignment of the sample both by optical and Xray (scattering and fluorescence) techniques, assessment of the diffraction quality of the sample, and SAD/MAD or nonconventional diffraction data acquisition with high-throughput data rates. The system covers all experimental steps required for protein x-ray structure analysis and provides a powerful means for structural genomics projects.
引用
收藏
页码:1519 / 1522
页数:4
相关论文
共 8 条
[1]   Automation of X-ray crystallography [J].
Abola, E ;
Kuhn, P ;
Earnest, T ;
Stevens, RC .
NATURE STRUCTURAL BIOLOGY, 2000, 7 (Suppl 11) :973-977
[2]   The protein crystallography beamline BW6 at DORIS -: automatic operation and high-throughput data collection [J].
Blume, H ;
Bösecke, P ;
Bourenkov, GP ;
Kosciesza, D ;
Bartunik, HD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 (PART II) :1358-1362
[3]  
DEACON A, 2001, INSTALLATION TESTING
[4]  
Gonzalez R.C., 1992, DIGITAL IMAGE PROCES
[5]  
KARAIN WI, 2002, UNPUB
[6]   Automated crystal mounting and data collection for protein crystallography [J].
Muchmore, SW ;
Olson, J ;
Jones, R ;
Pan, J ;
Blum, M ;
Greer, J ;
Merrick, SM ;
Magdalinos, P ;
Nienaber, VL .
STRUCTURE, 2000, 8 (12) :R243-R246
[7]   FIP:: a highly automated beamline for multiwavelength anomalous diffraction experiments [J].
Roth, M ;
Carpentier, P ;
Kaïkati, O ;
Joly, J ;
Charrault, P ;
Pirocchi, M ;
Kahn, R ;
Fanchon, E ;
Jacquamet, L ;
Borel, F ;
Bertoni, A ;
Israel-Gouy, P ;
Ferrer, JL .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2002, 58 :805-814
[8]   AUTOMATIC-MEASUREMENT OF SISTER CHROMATID EXCHANGE FREQUENCY [J].
ZACK, GW ;
ROGERS, WE ;
LATT, SA .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1977, 25 (07) :741-753