Simultaneous determination of thirteen β-blockers and one metabolite by gradient high-performance liquid chromatography with photodiode-array UV detection

被引:133
作者
Delamoye, M
Duverneuil, C
Paraire, F
de Mazancourt, P
Alvarez, JC
机构
[1] Ctr Hosp Univ Raymond Poincare, Serv Med Legale, AP HP, F-92380 Garches, France
[2] Ctr Hosp Univ Raymond Poincare, Lab Pharmacol Toxicol, F-92380 Garches, France
关键词
beta-blockers; HPLC; photodiode-array;
D O I
10.1016/j.forsciint.2003.12.008
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 [法学]; 10 [医学];
摘要
A new rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed for the simultaneous identification and quantification in human plasma of the 13 most commonly prescribed beta-blockers and one active metabolite-atenolol, sotatol, diacetolol, carteolol, nadolol, pindolol, acebutolol, metoprolol, celiprolol, oxprepolol, labetalol, propranolol, tertatolol and betaxolol. It involves liquid-liquid extraction procedures followed by liquid chromatography coupled to photodiode-array UV detection with a fixed wavelength at 220 nm for quantification. Compounds were separated on a 5 mum Hypurity C-18 (ThermoHypersil) analytical column (250 mm x 4.6 mm, i.d.) using a gradient of acetonitrile-phosphate buffer pH 3.8 at a flow rate of 1.0 ml/min. The total analysis time was 26 min per sample. Extraction recoveries were between 74 and 113% for the polar compounds and between 20 and 56% for the most apolar compounds. Calibration lines were linear in the range from 25 to 1000 ng/ml for all compounds excepted carteolol and nadolol (50-1000 ng/ml), all of them with coefficients of determination (r(2) values) greater than or equal to0.994. Limits of detection (LODs) ranged from 5 to 10 ng/ml. Intra-assay and inter-assay precision and accuracy were studied at two concentration levels (100 and 500 ng/ml). The intra-assay coefficients of variation (CVs) for all compounds were less than or equal to8.3% and all inter-assays CVs were below 12.6%. The intra-assay and inter-assay accuracies for all compounds were found to be within 91.4 and 105.6% at 100 ng/ml and within 94.1 and 107.4% at 500 ng/ml. Thus, the performance of the method described allows its use in toxicological screening and in quantification of the most prescribed beta-blockers drugs. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 22 条
[1]
Detection of beta-blockers in human urine by GC-MS-MS-EI:: perspectives for the antidoping control [J].
Amendola, L ;
Molaioni, F ;
Botrè, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (01) :211-221
[2]
Optimization of mobile phase in the separation of β-blockers by HPLC [J].
Basci, NE ;
Temizer, A ;
Bozkurt, A ;
Isimer, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :745-750
[3]
PHARMACOLOGICAL PROPERTIES OF DIACETOLOL (M+B 16,942), A MAJOR METABOLITE OF ACEBUTOLOL [J].
BASIL, B ;
JORDAN, R .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1982, 80 (01) :47-56
[4]
A fatal case of betaxolol poisoning [J].
Berthault, F ;
Kintz, P ;
Tracqui, A ;
Mangin, P .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (03) :228-231
[5]
DETERMINATION OF BETAXOLOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
CANAL, M ;
FLOUVAT, B .
JOURNAL OF CHROMATOGRAPHY, 1985, 342 (01) :212-215
[6]
Automated liquid chromatographic determination of atenolol in plasma using dialysis and trace enrichment on a cation-exchange precolumn for sample handling [J].
Chiap, P ;
Buraglia, BM ;
Ceccato, A ;
Hubert, P ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01) :205-217
[7]
Gergov M, 2000, J MASS SPECTROM, V35, P912, DOI 10.1002/1096-9888(200007)35:7<912::AID-JMS19>3.0.CO
[8]
2-4
[9]
SIMPLE AND RAPID ANALYSIS OF ATENOLOL AND METOPROLOL IN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARRISON, PM ;
TONKIN, AM ;
MCLEAN, AJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 339 (02) :429-433
[10]
IMPROVED SCREENING METHOD FOR BETA-BLOCKERS IN URINE USING SOLID-PHASE EXTRACTION AND CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
LELOUX, MS ;
DEJONG, EG ;
MAES, RAA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 488 (02) :357-367