X-ray microtomography (mu CT) using phase contrast for the investigation of organic matter

被引:143
作者
Beckmann, F [1 ]
Bonse, U [1 ]
Busch, F [1 ]
Gunnewig, O [1 ]
机构
[1] UNIV DORTMUND,INST PHYS,D-44227 DORTMUND,GERMANY
关键词
computed microtomography; computed tomography; apparatus and equipment; animal studies; techniques;
D O I
10.1097/00004728-199707000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: We show that microtomography (mu CT) using synchrotron radiation (SR) can be extended to include X-ray phase contrast, which is two to three orders of magnitude more sensitive than conventional attenuation contrast and better suited for the investigation of specimens consisting chiefly of light elements for photon energies ranging at least from 1 to 100 keV. Method: Phase contrast is generated by placing the specimen in one of the interfering beams of an X-ray interferometer. With use of 12-keV X-rays, phase projections of the specimen are recorded at 180 or 360 angular settings equally spaced between 0 and 180 degrees. One phase projection consists of four pairs of ''associated'' radiograms in the sense that one is taken with and the other without the specimen in the beam. Between pairs a parallel-sided phase-shifter plate is rotated for changing the relative phase of the two interfering beams by multiples of pi/2 rad. By calculating phase weighted sums of all associated pairs of radiograms, true phase-shift projections are obtained for all angular settings of the specimen, which are then reconstructed. Results: Three-dimensional images have been obtained from rat cerebrum and rat trigeminal nerve, showing cell structures at 8- to 15-mu m spatial resolution. Gray and white matter of cerebrum and neurons in the trigeminal nerve are clearly visible. Conclusion: X-ray phase-contrast mu CT is becoming a valuable tool for studies of organic samples in medicine and biology.
引用
收藏
页码:539 / 553
页数:15
相关论文
共 29 条
[1]
[Anonymous], TOP APPL PHYS
[2]
BECKMANN F, 1995, HASYLAB ANN REP, V2, P691
[3]
AN X-RAY INTERFEROMETER WITH LONG SEPARATED INTERFERING BEAM PATHS (E) [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 7 (04) :99-&
[4]
3D COMPUTED X-RAY TOMOGRAPHY OF HUMAN CANCELLOUS BONE AT 8 MU-M SPATIAL AND 10(-4) ENERGY RESOLUTION [J].
BONSE, U ;
BUSCH, F ;
GUNNEWIG, O ;
BECKMANN, F ;
PAHL, R ;
DELLING, G ;
HAHN, M ;
GRAEFF, W .
BONE AND MINERAL, 1994, 25 (01) :25-38
[5]
BONSE U, 1991, J MATER SCI, V26, P4076, DOI 10.1007/BF02402949
[6]
X-ray computed microtomography (mu CT) using synchrotron radiation (SR) [J].
Bonse, U ;
Busch, F .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 (1-2) :133-169
[7]
RECENT ADVANCES IN X-RAY AND NEUTRON INTERFEROMETRY [J].
BONSE, U .
PHYSICA B & C, 1988, 151 (1-2) :7-21
[8]
AN X-RAY INTERFEROMETER [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 6 (08) :155-&
[9]
Bonse U., 1996, ESRF NEWSLETTER, P21
[10]
BUSCH F, 1995, HASYLAB ANN REP, V2, P689