No functional impairment after Robodoc total hip arthroplasty -: Gait analysis in 25 patients

被引:31
作者
Bach, CM
Winter, P
Nogler, M
Göbel, G
Wimmer, C
Ogon, M
机构
[1] Univ Innsbruck, Dept Orthopaed Surg, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Dept Biostat, A-6020 Innsbruck, Austria
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2002年 / 73卷 / 04期
关键词
D O I
10.1080/00016470216316
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Robodoc total hip replacement procedure requires a wider exposure of the proximal femur, especially of the greater trochanter, than the standard procedure. Moreover, the leg must be placed in a rigid leg-holder apparatus to obtain fixation in maximal hip adduction and external rotation. This may impair the hip abductors and reduce hip abduction in the mid- and terminal stance phase of the cycle. In this study we compared patients after Robodoc and conventional total hip arthroplasty with three-dimensional gait analysis (VICON System, Oxford Metrics, Oxford, U.K.) to assess the kinematics of the pelvis and hip. 25 patients underwent total hip replacement by means of the Robodoc total hip arthroplasty system, 25 patients were treated with conventional total hip replacement, and 40 healthy volunteers served as controls. None of the patients undergoing total hip replacement, robotic or conventional, obtained normal kinematic gait patterns 6 months after surgery. However, the reduction in hip abduction did not differ significantly in patients undergoing robotic or conventional total hip arthroplasty, which suggests that the robotic procedure did not impair hip abductor function more than the conventional method.
引用
收藏
页码:386 / 391
页数:6
相关论文
共 20 条
[1]
PLANNING POLICIES AND DEVELOPMENT CONTROL IN THE SUSSEX DOWNS AONB [J].
ANDERSON, MA .
TOWN PLANNING REVIEW, 1981, 52 (01) :5-25
[2]
Bargar WL, 1998, CLIN ORTHOP RELAT R, P82
[3]
TRANSGLUTEAL APPROACH TO THE HIP-JOINT [J].
BAUER, R ;
KERSCHBAUMER, F ;
POISEL, S ;
OBERTHALER, W .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (1-2) :47-49
[4]
THE TRANSGLUTEAL APPROACH FOR THE IMPLANTATION OF ARTIFICIAL HIP JOINTS [J].
BAUER, R ;
RUSSE, W .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1984, 122 (01) :48-49
[5]
BERMAN AT, 1987, J BONE JOINT SURG AM, V69A, P1340
[6]
Robot-assisted surgery in total hip replacement [J].
Borner, M ;
Bauer, A ;
Lahmer, A .
UNFALLCHIRURG, 1997, 100 (08) :640-645
[7]
Borner M, 1997, ORTHOPADE, V26, P251
[8]
KINETIC-ANALYSIS OF THE LOWER-LIMBS DURING WALKING - WHAT INFORMATION CAN BE GAINED FROM A 3-DIMENSIONAL MODEL [J].
ENG, JJ ;
WINTER, DA .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :753-758
[9]
Finley F R, 1969, Arch Phys Med Rehabil, V50, P140
[10]
Gage JR., 1991, Gait Analysis in Cerebral Palsy