Dust mite allergens are carried on not only large particles

被引:42
作者
Custovic, A [1 ]
Woodcock, H [1 ]
Craven, M [1 ]
Hassall, R [1 ]
Hadley, E [1 ]
Simpson, A [1 ]
Woodcock, A [1 ]
机构
[1] Wythenshawe Hosp, NW Lung Ctr, Manchester M23 9LT, Lancs, England
关键词
mite; allergens; der p 2; aerodynamics;
D O I
10.1034/j.1399-3038.1999.00050.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The major obstacle for the successful measurement of airborne mite allergen is its very low concentration in the absence of vigorous disturbance. The aim of this study was to investigate the particle size distribution of group 2 dust mite allergen using an amplified ELISA system. Air sampling was performed using an Andersen sampler placed in the centre of the room, 1.2 m above floor level (airflow rate 28.7 l/min). This is a multistage, multiorifice cascade impactor that is comprised of six stages. Any particle greater that 4.7 mu m should impact on stages 1 and 2, whilst stages 3-6 measure the predominantly respiratory range. The sampling was carried out for 30 min after 15 min of vigorous disturbance (vacuum cleaning without bag and filter). Der p 2 was measured using mAb-based ELISA with the AmpliQ amplification kit (Dako Ltd, Cambridgeshire, UK). The sensitivity was increased 15-fold as compared with standard assay, bringing the level of detection to 300 pg/ml. The majority of airborne Der p 2 (79.4%) was carried on large particles (> 4.7 mu m). However, a small but important proportion of airborne Der p 2 (20.6%) was associated with small particles (1.1-4.7 mu m) It is worth noting that all the levels measured were below the detection limit of standard assay. In conclusion, we have shown that using an amplification system, airborne mite allergen previously undetectable owing to its low concentration can be quantified. Group 2 dust mite allergen is carried not only on large particles. A small, but potentially significant proportion of this airborne allergen is associated with small particles which, when inhaled, may penetrate deep into the human respiratory tract.
引用
收藏
页码:258 / 260
页数:3
相关论文
共 10 条
[1]   Distribution, aerodynamic characteristics, and removal of the major cat allergen Fel d 1 in British homes [J].
Custovic, A ;
Simpson, A ;
Pahdi, H ;
Green, RM ;
Chapman, MD ;
Woodcock, A .
THORAX, 1998, 53 (01) :33-38
[2]   Aerodynamic properties of the major dog allergen Can f 1: Distribution in homes, concentration, and particle size of allergen in the air [J].
Custovic, A ;
Green, R ;
Fletcher, A ;
Smith, A ;
Pickering, CAC ;
Chapman, MD ;
Woodcock, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (01) :94-98
[3]   Mite allergen (Der p 1) is not only carried on mite feces [J].
De Lucca, S ;
Sporik, R ;
O'Meara, T ;
Tovey, ER .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) :174-175
[4]   AIRBORNE DUST MITE ALLERGENS - COMPARISON OF GROUP II ALLERGENS WITH GROUP-I MITE ALLERGEN AND CAT-ALLERGEN FEL D I [J].
DEBLAY, F ;
HEYMANN, PW ;
CHAPMAN, MD ;
PLATTSMILLS, TAE .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1991, 88 (06) :919-926
[5]   DUST MITE ALLERGENS AND ASTHMA - A WORLDWIDE PROBLEM [J].
PLATTSMILLS, TAE ;
DEWECK, AL .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 83 (02) :416-427
[6]   MEASUREMENT OF AIRBORNE MITE ANTIGEN IN HOMES OF ASTHMATIC-CHILDREN [J].
PRICE, JA ;
POLLOCK, I ;
LITTLE, SA ;
LONGBOTTOM, JL ;
WARNER, JO .
LANCET, 1990, 336 (8720) :895-897
[7]   MEASUREMENT OF ALLERGENS ASSOCIATED WITH DUST MITE ALLERGY .2. CONCENTRATIONS OF AIRBORNE MITE ALLERGENS (DER-I AND DER-II) IN THE HOUSE [J].
SAKAGUCHI, M ;
INOUYE, S ;
YASUEDA, H ;
IRIE, T ;
YOSHIZAWA, S ;
SHIDA, T .
INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1989, 90 (02) :190-193
[8]   CONCENTRATION OF AIRBORNE MITE ALLERGENS (DER-I AND DER-II) DURING SLEEP [J].
SAKAGUCHI, M ;
INOUYE, S ;
YASUEDA, H ;
SHIDA, T .
ALLERGY, 1992, 47 (01) :55-57
[9]   CORRELATIONS BETWEEN LEVELS OF MITE AND CAT ALLERGENS IN SETTLED AND AIRBORNE DUST [J].
SWANSON, MC ;
CAMPBELL, AR ;
KLAUCK, MJ ;
REED, CE .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 83 (04) :776-783
[10]  
TOVEY ER, 1981, AM REV RESPIR DIS, V124, P630