DETERMINATION OF COPPER IN WATER BY IONIC LIQUID BASED MICROEXTRACTION AND CHEMILUMINESCENCE DETECTION

被引:12
作者
Abolhasani, Jafar [1 ]
Amjadi, Mohammad [2 ]
Hassanzadeh, Javad [2 ]
Ghorbani-Kalhor, Ebrahim [1 ]
机构
[1] Islamic Azad Univ, Tabriz Branch, Dept Chem, Fac Sci, Tabriz, Iran
[2] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz, Iran
关键词
Chemiluminescence; Copper; Dispersive liquid-liquid extraction; Microextraction; Temperature controlled; Ultrasound assisted; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; SOLID-PHASE EXTRACTION; FLOW-INJECTION; SPECTROPHOTOMETRIC DETERMINATION; TRACE AMOUNTS; ENVIRONMENTAL-SAMPLES; HUMAN HAIR; ICP-OES; PRECONCENTRATION;
D O I
10.1080/00032719.2013.878839
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A versatile, sensitive, and green method based ultrasound-assisted, temperature-controlled, dispersive liquid-liquid microextraction with an ionic liquid and chemiluminescence detection was used for the determination of copper(II) at the ultra-trace level. After complexation by dithizone, copper(II) was extracted into the ionic liquid. Using high temperature and ultrasonic agitation, the copper complex easily migrated into the ionic liquid phase because of the larger contact area. After back extraction, the determination was performed by chemiluminescence based on the catalyzing effect of copper(II) on the decomposition of hydrogen peroxide with rhodamine B. Important parameters that affected the extraction efficiency and chemiluminescence intensity were optimized. Under the optimum conditions, a limit of detection for copper of 0.8 ng L-1 was obtained with a linear calibration relationship. The method was applied to analyze environmental water samples for copper(II) with satisfactory results.
引用
收藏
页码:1528 / 1540
页数:13
相关论文
共 38 条
[1]
Spectrophotometric determination of copper in waste water using liquid-liquid extraction in a flow-injection system [J].
Alonso, A ;
Almendral, MJ ;
Curto, Y ;
Porras, MJ .
MICROCHIMICA ACTA, 2003, 143 (04) :217-220
[2]
Ultrasound Assisted-Temperature Controlled Ionic Liquid Microextraction of Trace Copper and Silver after Chelation with Dithizone and Their Determination by Flame Atomic Absorption Spectrometry in Food and Water Samples [J].
Amjadi, Mohammad ;
Manzoori, Jamshid L. ;
Hashemzadeh, Shabnam .
CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (04) :668-674
[3]
On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 79 (01) :86-91
[4]
Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry [J].
Berton, Paula ;
Martinis, Estefania M. ;
Martinez, Luis D. ;
Wuilloud, Rodolfo G. .
ANALYTICA CHIMICA ACTA, 2012, 713 :56-62
[5]
Separation and preconcentration system based on ultrasonic probe-assisted ionic liquid dispersive liquid liquid microextraction for determination trace amount of chromium(VI) by electrothermal atomic absorption spectrometry [J].
Chen, Hao ;
Du, Ping ;
Chen, Jie ;
Hu, Shenghua ;
Li, Shengqing ;
Liu, Hanlan .
TALANTA, 2010, 81 (1-2) :176-179
[6]
Ion pair-based dispersive liquid-liquid microextraction for gold determination at ppb level in solid samples after ultrasound-assisted extraction and in waters by electrothermal-atomic absorption spectrometry [J].
De la Calle, I. ;
Pena-Pereira, F. ;
Cabaleiro, N. ;
Lavilla, I. ;
Bendicho, C. .
TALANTA, 2011, 84 (01) :109-115
[7]
COPPER TOXICITY AND CHEMISTRY IN THE ENVIRONMENT - A REVIEW [J].
FLEMMING, CA ;
TREVORS, JT .
WATER AIR AND SOIL POLLUTION, 1989, 44 (1-2) :143-158
[8]
Dispersive liquid-liquid microextraction based on ionic liquid and spectrophotometric determination of mercury in water samples [J].
Gharehbaghi, Maysam ;
Shemirani, Farzaneh ;
Baghdadi, Majid .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (01) :21-33
[10]
Flow injection chemiluminescence determination of hemin using the rhodamine B-H2O2-NaOH system [J].
Han, SQ ;
Liu, EB ;
Li, H .
MICROCHIMICA ACTA, 2005, 149 (3-4) :281-286