Phosphorescence imaging system using an acousto-optic filter-based charge coupled device

被引:5
作者
Campiglia, AD [1 ]
Moreau, F [1 ]
Hueber, DM [1 ]
Vo-Dinh, T [1 ]
机构
[1] OAK RIDGE NATL LAB, HLTH SCI RES DIV, ADV MONITORING DEV GRP, OAK RIDGE, TN 37831 USA
关键词
phosphorescence; imaging detection; polyaromatic hydrocarbons; acousto-optic tunable filter;
D O I
10.1016/S0003-2670(97)00236-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are reporting for the first time the development of an imaging spectrometer for solid surface room temperature phosphorimetry based on an acousto-optic tunable filter. A He-Cd laser was employed as the excitation source, and a cooled two-dimensional charge coupled device was used as the detector. The spectral characterization and imaging capability of the new system were evaluated with two well known phosphorescent compounds. The phosphorescence emissions of pyrene and 1,2,3,4-dibenzanthracene adsorbed on chromatography paper treated for background reduction were investigated. Thallium(I) acetate was employed as a phosphorescence enhancer. Based on the performance of the proposed instrument, several potential applications are discussed. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:229 / 239
页数:11
相关论文
共 48 条
[1]   SELECTIVE ENHANCEMENT OF ROOM-TEMPERATURE PHOSPHORESCENCE USING CYCLODEXTRIN-TREATED CELLULOSE SUBSTRATE [J].
ALAK, AM ;
VO-DINH, T .
ANALYTICAL CHEMISTRY, 1988, 60 (06) :596-600
[2]   MULTICOMPONENT MIXTURE ANALYSIS USING ROOM-TEMPERATURE PHOSPHORIMETRY [J].
ASAFUADJAYE, EB ;
YUN, JI ;
SU, SY .
ANALYTICAL CHEMISTRY, 1985, 57 (04) :904-907
[3]   AN EVALUATION OF CELLULOSE AS A SUBSTRATE FOR ROOM-TEMPERATURE PHOSPHORESCENCE [J].
BATEH, RP ;
WINEFORDNER, JD .
TALANTA, 1982, 29 (08) :713-717
[4]   Analysis of polycyclic aromatic compounds in soil samples using laser-induced phosphorimetry [J].
Campiglia, AD ;
Hueber, DM ;
VoDinh, T .
POLYCYCLIC AROMATIC COMPOUNDS, 1996, 8 (2-3) :117-128
[5]   ROOM-TEMPERATURE PHOSPHORIMETRY OF CARBARYL IN LOW-BACKGROUND PAPER [J].
CAMPIGLIA, AD ;
DELIMA, CG .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2822-2827
[6]   SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORIMETRIC DETECTION OF CAFFEINE, THEOPHYLLINE AND THEOBROMINE IN LIQUID-CHROMATOGRAPHY [J].
CAMPIGLIA, AD ;
LASERNA, JJ ;
BERTHOD, A ;
WINEFORDNER, JD .
ANALYTICA CHIMICA ACTA, 1991, 244 (02) :215-222
[7]   SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CAMPIGLIA, AD ;
BERTHOD, A ;
WINEFORDNER, JD .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :37-49
[8]  
CHANG IC, 1992, P SOC PHOTO-OPT INS, V1703, P24, DOI 10.1117/12.138427
[9]   ACOUSTOOPTIC TUNABLE FILTERS [J].
CHANG, IC .
OPTICAL ENGINEERING, 1981, 20 (06) :824-829
[10]  
CHAO TH, 1990, P SOC PHOTO-OPT INS, V1347, P655, DOI 10.1117/12.23455