Fatal complications after use of the symmetry aortic connector in coronary artery bypass surgery

被引:12
作者
Lahtinen, J
Biancari, F
Mosorin, M
Heikkinen, J
Rainio, P
Juvonen, TS
Lepojärvi, M
机构
[1] Oulu Univ Hosp, Dept Surg, Div Cardiothorac & Vasc Surg, Oys 90029, Finland
[2] Univ Oulu, Dept Surg, Div Cardiothorac & Vasc Surg, Oulu, Finland
关键词
D O I
10.1016/S0003-4975(03)01291-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During the last 2 years, 103 aortic saphenous vein graft anastomoses were performed in 68 patients undergoing off-pump coronary artery bypass by using the Symmetry Bypass System Aortic Connector. Of these patients, 2 died during the early postoperative period. In the first patient, after an episode of ventricular fibrillation and closed-chest cardiac massage, the sternum was opened and hemopericardium secondary to leakage of the proximal anastomotic device was found. The second patient died of ascending aortic dissection, the tear of which was likely to have originated from the proximal anastomotic site. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:1817 / 1819
页数:3
相关论文
共 7 条
[1]   Assessment of an aortosaphenous vein graft anastomotic device in coronary surgery: Clinical experience and early angiographic results [J].
Antona, C ;
Scrofani, R ;
Lemma, M ;
Vanelli, P ;
Mangini, A ;
Danna, P ;
Gelpi, G .
ANNALS OF THORACIC SURGERY, 2002, 74 (06) :2101-2105
[2]   Thrombotic occlusion of the aortic ostia of saphenous venous grafts early after coronary artery bypass grafting by using the Symmetry aortic connector system [J].
Donsky, AS ;
Schussler, JM ;
Donsky, MS ;
Roberts, WC ;
Hamman, BL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) :397-399
[3]   The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Immer, FF ;
Berg, TA ;
Schmidli, J ;
Carrel, TP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :777-782
[4]   First experience with the St Jude Medical, Inc, Symmetry Bypass System (Aortic Connector System) [J].
Hornik, L ;
Tenderich, G ;
Minami, K ;
Fassbender, D ;
Schulz, TO ;
Beinert, B ;
Koerfer, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (02) :414-417
[5]   Early bypass occlusion in patients with the St Jude Medical Symmetry connector [J].
Reuthebuch, O ;
Lachat, M ;
Kadner, A ;
Turina, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (02) :443-444
[6]   Video-assisted multivessel revascularization through a left anterior small thoracotomy approach with the Symmetry Aortic Connector System [J].
Semrád, M ;
Bodlák, P ;
Strítesky, M ;
Vondrácek, V ;
Urban, T ;
Vyhnalová, P ;
Holm, F ;
Vanek, I .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (01) :129-134
[7]   Defining the role of anastomotic devices in coronary bypass surgery [J].
Yau, TM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (01) :27-29