Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates

被引:247
作者
Niu, JL [1 ]
Zhang, LZ [1 ]
Zuo, HG [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
commercial buildings; hot and humid; simulation; radiant cooling; desiccant cooling;
D O I
10.1016/S0378-7788(01)00132-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An heating, ventilating and air-conditioning (HVAC) system combining chilled-ceiling with desiccant cooling is proposed for hot and humid climates where air dehumidification is required to maintain the indoor air humidity within a comfort zone and to reduce the risk of water condensation on chilled panels. With this system, temperature and humidity control are decoupled by using desiccant wheel for moisture removal and ceiling panels for temperature control. To evaluate the system performance and the energy savings potential, another three systems: conventional all-air system, all-air system with total heat recovery, and radiant cooling with air handling unit (AHU), are considered for a typical office in Hong Kong. The hourly sensible load is calculated by a building energy simulation code ACCURACY and the latent load is predicted by moisture balance in the room. Through hour-by-hour simulations, the annual energy consumptions of the four systems are calculated and analyzed. The results indicate that chilled-ceiling combined with desiccant cooling could save up to 44% of primary energy consumption, in comparison with a conventional constant volume all-air system. More interestingly, more than 70% of annual operating hours for desiccant regeneration could be accomplished by low-grade heat of less than 80 degreesC. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:487 / 495
页数:9
相关论文
共 17 条
  • [1] [Anonymous], ASHRAE J
  • [2] [Anonymous], 1988, ASHRAE Transactions
  • [3] *ASHRAE, 1999, 62 ANSIASHRAE AM SOC
  • [4] ASHRAE, 1997, Handbook
  • [5] HYDRONIC RADIANT COOLING - PRELIMINARY ASSESSMENT
    FEUSTEL, HE
    STETIU, C
    [J]. ENERGY AND BUILDINGS, 1995, 22 (03) : 193 - 205
  • [6] Thermal comfort and energy consumption of the radiant ceiling panel system. Comparison with the conventional all-air system
    Imanari, T
    Omori, T
    Bogaki, K
    [J]. ENERGY AND BUILDINGS, 1999, 30 (02) : 167 - 175
  • [7] JURINAK JJ, 1983, P ASME SOL EN DIV 5, P374
  • [8] Performance of radiant cooling system integrated with ice storage
    Matsuki, N
    Nakano, Y
    Miyanaga, T
    Yokoo, N
    Oka, T
    [J]. ENERGY AND BUILDINGS, 1999, 30 (02) : 177 - 183
  • [9] Mertz G, 1992, AIR INFILTRATION REV, V13, P7
  • [10] INDOOR CLIMATE IN ROOMS WITH COOLED CEILING SYSTEMS
    NIU, J
    VANDERKOOI, J
    [J]. BUILDING AND ENVIRONMENT, 1994, 29 (03) : 283 - 290