Investigating the Tradeoffs Between Spatial Resolution and Diffusion Sampling for Brain Mapping with Diffusion Tractography: Time Well Spent?

被引:30
作者
Calabrese, Evan [1 ,2 ]
Badea, Alexandra [1 ]
Coe, Christopher L. [3 ]
Lubach, Gabriele R. [3 ]
Styner, Martin A. [4 ,5 ]
Johnson, G. Allan [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
[3] Univ Wisconsin, Dept Psychol, Harlow Ctr Biol Psychol, Madison, WI 53706 USA
[4] Univ N Carolina, Dept Comp Sci, Chapel Hill, NC USA
[5] Univ N Carolina, Dept Psychiat, Chapel Hill, NC USA
关键词
Macaca mulatta; diffusion magnetic resonance imaging; diffusion tensor imaging; connectome; neuroanatomy; FIBER PATHWAYS; GRADIENT DIRECTIONS; TENSOR TRACTOGRAPHY; GEOMETRIC STRUCTURE; AXONAL PROJECTIONS; MRI; RECONSTRUCTION; ARCHITECTURE; TRACKING; FEATURES;
D O I
10.1002/hbm.22578
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
Interest in mapping white matter pathways in the brain has peaked with the recognition that altered brain connectivity may contribute to a variety of neurologic and psychiatric diseases. Diffusion tractography has emerged as a popular method for postmortem brain mapping initiatives, including the ex-vivo component of the human connectome project, yet it remains unclear to what extent computer-generated tracks fully reflect the actual underlying anatomy. Of particular concern is the fact that diffusion tractography results vary widely depending on the choice of acquisition protocol. The two major acquisition variables that consume scan time, spatial resolution, and diffusion sampling, can each have profound effects on the resulting tractography. In this analysis, we determined the effects of the temporal tradeoff between spatial resolution and diffusion sampling on tractography in the ex-vivo rhesus macaque brain, a close primate model for the human brain. We used the wealth of autoradiography-based connectivity data available for the rhesus macaque brain to assess the anatomic accuracy of six time-matched diffusion acquisition protocols with varying balance between spatial and diffusion sampling. We show that tractography results vary greatly, even when the subject and the total acquisition time are held constant. Further, we found that focusing on either spatial resolution or diffusion sampling at the expense of the other is counterproductive. A balanced consideration of both sampling domains produces the most anatomically accurate and consistent results. Hum Brain Mapp 35:5667-5685, 2014. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:5667 / 5685
页数:19
相关论文
共 61 条
[1]
Orientationally invariant indices of axon diameter and density from diffusion MRI [J].
Alexander, Daniel C. ;
Hubbard, Penny L. ;
Hall, Matt G. ;
Moore, Elizabeth A. ;
Ptito, Maurice ;
Parker, Geoff J. M. ;
Dyrby, Tim B. .
NEUROIMAGE, 2010, 52 (04) :1374-1389
[2]
Axer Markus, 2011, Front Neuroinform, V5, P34, DOI 10.3389/fninf.2011.00034
[3]
Barmpoutis A, 2009, LECT NOTES COMPUT SC, V5636, P338, DOI 10.1007/978-3-642-02498-6_28
[4]
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[5]
2-O
[6]
Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[7]
Relationships between diffusion tensor and q-space MRI [J].
Basser, PJ .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :392-397
[8]
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[9]
NMR MICROSCOPY OF DYNAMIC DISPLACEMENTS - K-SPACE AND Q-SPACE IMAGING [J].
CALLAGHAN, PT ;
ECCLES, CD ;
XIA, Y .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (08) :820-822
[10]
Comment on "The Geometric Structure of the Brain Fiber Pathways" [J].
Catani, Marco ;
Bodi, Istvan ;
Dell'Acqua, Flavio .
SCIENCE, 2012, 337 (6102)