VELOCITY VARIABILITY IN ULTRASONIC DOPPLER EXAMINATIONS

被引:6
作者
Hadlock, Jean [1 ]
Beach, Kirk W. [1 ,2 ]
机构
[1] Univ Washington, Div Vasc Surg, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
Carotid; Doppler; Variability; CAROTID-ARTERY STENOSIS; FLOW; DIAGNOSIS; CIRCLE; WILLIS;
D O I
10.1016/j.ultrasmedbio.2008.12.012
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Ultrasonic Doppler examination with spectral waveform has been used for the classification and surveillance of carotid artery stenosis for over 25 years. Progression/regression between examinations can be identified with 95% confidence if the velocity measurements change by more than two times the root mean square difference (RMSD) of the repeat measurement. Peak systolic velocity and end diastolic velocity measurements at a Doppler angle of 60 degrees were repeated in 47 carotid examinations. Measurement difference between sonographers and between instruments was tabulated. Root mean square difference was 11 cm/s(RMS% D = 11%) for systolic and 7 cm/s (RMS% D = 21%) for diastolic velocity measurements (excluding one severe stenosis case). Results for differences between sonographers and between instruments were similar to the overall results. In serial arterial studies using this Doppler velocimetry method, a difference exceeding 23 cm/s (21%) systolic, or 14 cm/s (42%) diastolic velocity indicates a significant (2 X RMSD) hemodynamic change. (E-mail: kwbeach@u.washington.edu) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 17 条
[1]
ULTRASONIC DUPLEX ECHO-DOPPLER SCANNER [J].
BARBER, FE ;
BAKER, DW ;
NATION, AWC ;
STRANDNESS, DE ;
REID, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1974, BM21 (02) :109-113
[2]
BLACKSHEAR WM, 1979, SURGERY, V86, P698
[3]
BODILY KC, 1980, SURG GYNECOL OBSTET, V151, P77
[4]
Interobserver variability of carotid Doppler peak velocity measurcments among technologists in an ICAVL-accredited vascular laboratory [J].
Corriveau, MM ;
Johnston, KW .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (04) :735-741
[5]
Carotid artery stenosis: Gray-scale and Doppler US diagnosis - Society of Radiologists in Ultrasound consensus conference [J].
Grant, EG ;
Benson, CB ;
Moneta, GL ;
Alexandrov, AV ;
Baker, JD ;
Bluth, EI ;
Carroll, BA ;
Eliasziw, M ;
Gocke, J ;
Hertzberg, BS ;
Katanick, S ;
Needleman, L ;
Pellerito, J ;
Polak, JF ;
Rholl, KS ;
Wooster, DL ;
Zierler, E .
RADIOLOGY, 2003, 229 (02) :340-346
[6]
HODSON CJ, 1973, CAN MED ASSOC J, V108, P1391
[7]
COURSE OF CAROTID-ARTERY OCCLUSIONS WITH IMPAIRED CEREBROVASCULAR REACTIVITY [J].
KLEISER, B ;
WIDDER, B .
STROKE, 1992, 23 (02) :171-174
[8]
A SIMPLE PARAMETER FOR ACCURATE DETECTION OF SEVERE CAROTID DISEASE [J].
KNOX, RA ;
BRESLAU, PJ ;
STRANDNESS, DE .
BRITISH JOURNAL OF SURGERY, 1982, 69 (04) :230-233
[9]
VARIABILITY IN MEASUREMENT OF SPECIFIC PARAMETERS FOR CAROTID DUPLEX EXAMINATION [J].
KOHLER, TR ;
LANGLOIS, Y ;
ROEDERER, GO ;
PHILLIPS, DJ ;
BEACH, KW ;
PRIMOZICH, J ;
LAWRENCE, R ;
NICHOLLS, SC ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (10) :637-642
[10]
HEMODYNAMICS OF THE NORMAL HUMAN CAROTID BIFURCATION - INVITRO AND INVIVO STUDIES [J].
KU, DN ;
GIDDENS, DP ;
PHILLIPS, DJ ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (01) :13-26