In vitro estimation of foetal liver volume using ultrasound, x-ray computed tomography and magnetic resonance imaging

被引:4
作者
Hughes, SW [1 ]
DArcy, TJ [1 ]
Maxwell, DJ [1 ]
Saunders, JE [1 ]
机构
[1] GUYS & ST THOMAS HOSP TRUST,DEPT OBSTET & GYNAECOL,LONDON SE1 7EH,ENGLAND
关键词
volume; computed tomography; magnetic resonance; three-dimensional ultrasound;
D O I
10.1088/0967-3334/18/4/011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Sixteen formalin-fixed foetal livers were scanned in vitro using a new system for estimating volume from a sequence of multiplanar 2D ultrasound images. Three different scan techniques were used (radial, parallel and slanted) and four volume estimation algorithms (ellipsoid, planimetry, tetrahedral and ray tracing). Actual liver volumes were measured by water displacement. Twelve of the sixteen livers also received x-ray computed tomography (CT) and magnetic resonance (MR) scans and the volumes were calculated using voxel counting and planimetry. The percentage accuracy (mean +/- SD) was 5.3 +/- 4.7%, -3.1 +/- 9.6% and -0.03 +/- 9.7% for ultrasound (radial scans, ray volumes), MR and CT (voxel counting) respectively. The new system may be useful for accurately estimating foetal liver volume in utero.
引用
收藏
页码:401 / 410
页数:10
相关论文
共 20 条
[1]   ESTIMATION OF FETAL LUNG-VOLUME USING ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING [J].
BAKER, PN ;
JOHNSON, IR ;
GOWLAND, PA ;
FREEMAN, A ;
ADAMS, V ;
MANSFIELD, P .
OBSTETRICS AND GYNECOLOGY, 1994, 83 (06) :951-954
[2]   MEASUREMENT OF FETAL LIVER, BRAIN AND PLACENTAL VOLUMES WITH ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING [J].
BAKER, PN ;
JOHNSON, IR ;
GOWLAND, PA ;
HYKIN, J ;
ADAMS, V ;
MANSFIELD, P ;
WORTHINGTON, BS .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (01) :35-39
[3]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[4]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P159, DOI 10.1016/0301-5629(79)90084-X
[5]   FACTORS AFFECTING THE MEASUREMENT OF SIZE AND CT-NUMBER IN COMPUTED-TOMOGRAPHY [J].
BAXTER, BS ;
SORENSON, JA .
INVESTIGATIVE RADIOLOGY, 1981, 16 (04) :337-341
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   CORRECTION OF DISTORTION IN US IMAGES CAUSED BY SUBCUTANEOUS TISSUES - RESULTS IN TISSUE PHANTOMS AND HUMAN-SUBJECTS [J].
CARPENTER, DA ;
KOSSOFF, G ;
GRIFFITHS, KA .
RADIOLOGY, 1995, 195 (02) :563-567
[8]   Estimation of fetal lung volume using enhanced 3-dimensional ultrasound: A new method and first result [J].
DArcy, TJ ;
Hughes, SW ;
Chiu, WSC ;
Clark, T ;
Milner, AD ;
Saunders, J ;
Maxwell, D .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1996, 103 (10) :1015-1020
[9]  
Gopal A S, 1992, J Am Soc Echocardiogr, V5, P115
[10]   THE EFFECT ON APPARENT SIZE OF SIMULATED PULMONARY NODULES OF USING 3 STANDARD CT WINDOW SETTINGS [J].
HARRIS, KM ;
ADAMS, H ;
LLOYD, DCF ;
HARVEY, DJ .
CLINICAL RADIOLOGY, 1993, 47 (04) :241-244