摘要
Mechanical trauma caused by percutaneous coronary intervention is a major factor contributing to subsequent cardiac events, restenosis, and the need for target lesion revascularization (TLR). To minimize this trauma,we developed a Computerized Angioplasty Pressure Sensor and Inflator Device (CAPSID) for gradual inflation. The objective of the present prospective randomized study was to examine whether the use of this novel device reduced TLR, as well as cardiac events, in patients undergoing stenting. Patients undergoing coronary stenting were eligible and randomized to receive CAPSID or standard manual percutaneous coronary intervention. In the CAPSID group, slow, gradual balloon inflation was performed using a personal computer. Patients with acute ST-elevation myocardial infarction or the need for percutaneous coronary intervention for total occlusions, left main disease, and vein grafts were excluded. Clinical follow-up for major adverse cardiac events, including death, acute myocardial infarction, and TLR, was performed at 12 months. A total of 310 patients were enrolled in the study. No significant differences were found in the clinical characteristics between the CAPSID and control groups. At I year of follow-up, the CAPSID group had had a significantly lower rate of major adverse cardiac events (8% vs 18%, p < 0.01) driven by significantly lower rates of acute myocardial infarction (1% vs 7%, p < 0.01) and TLR (5% vs 12%, p < 0.05). In conclusion, gradual computerized balloon inflation using CAPSID as a platform for angioplasty and stenting significantly reduced TLR and major adverse cardiac events at 1 year in patients undergoing coronary stenting. The use of this novel device may improve outcomes in patients undergoing coronary stenting. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;104:223-226)
引用
收藏
页码:223 / 226
页数:4
相关论文
共 13 条
[1]   CORONARY ANGIOPLASTY WITH GRADUAL VERSUS RAPID BALLOON INFLATION - INITIAL RESULTS AND COMPLICATIONS [J].
ILIA, R ;
CABIN, H ;
MCCONNELL, S ;
CLEMAN, M ;
REMETZ, M .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (03) :199-202
[2]   Computerized gradual balloon inflation: a novel strategy of coronary angioplasty superior to a standard manual approach [J].
Leibowitz, David ;
Abu-Gazala, Mahmoud ;
Katz, Iony ;
Danenberg, Haim ;
Nassar, Hisham ;
Boguslavsky, Larissa ;
Mosseri, Morris ;
Varshitzs, Boris ;
Lotan, Chaim ;
Weiss, A. Teddy .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2009, 10 (01) :45-48
[3]   ANGIOGRAPHIC-PATHOLOGICAL CORRELATIONS AFTER ELECTIVE PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
NARUKO, T ;
UEDA, M ;
BECKER, AE ;
TOJO, O ;
TERAGAKI, M ;
TAKEUCHI, K ;
TAKEDA, T .
CIRCULATION, 1993, 88 (04) :1558-1568
[4]   RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - PATHOLOGICAL OBSERVATIONS IN 20 PATIENTS [J].
NOBUYOSHI, M ;
KIMURA, T ;
OHISHI, H ;
HORIUCHI, H ;
NOSAKA, H ;
HAMASAKI, N ;
YOKOI, H ;
KIM, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) :433-439
[5]   A RANDOMIZED COMPARISON OF THE EFFECTS OF GRADUAL PROLONGED VERSUS STANDARD PRIMARY BALLOON INFLATION ON EARLY AND LATE OUTCOME - RESULTS OF A MULTICENTER CLINICAL-TRIAL [J].
OHMAN, EM ;
MARQUIS, JF ;
RICCI, DR ;
BROWN, RIG ;
KNUDTSON, ML ;
KEREIAKES, DJ ;
SAMAHA, JK ;
MARGOLIS, JR ;
NIEDERMAN, AL ;
DEAN, LS ;
GURBEL, PA ;
SKETCH, MH ;
WILDERMANN, NM ;
LEE, KL ;
CALIFF, RM .
CIRCULATION, 1994, 89 (03) :1118-1125
[6]   INFLUENCE OF BALLOON SIZE ON INITIAL SUCCESS, ACUTE COMPLICATIONS, AND RESTENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - A PROSPECTIVE RANDOMIZED STUDY [J].
ROUBIN, GS ;
DOUGLAS, JS ;
KING, SB ;
LIN, S ;
HUTCHISON, N ;
THOMAS, RG ;
GRUENTZIG, AR .
CIRCULATION, 1988, 78 (03) :557-565
[7]   INFLUENCE OF INFLATION PRESSURE AND BALLOON SIZE ON THE DEVELOPMENT OF INTIMAL HYPERPLASIA AFTER BALLOON ANGIOPLASTY - A STUDY IN THE ATHEROSCLEROTIC RABBIT [J].
SAREMBOCK, IJ ;
LAVEAU, PJ ;
SIGAL, SL ;
TIMMS, I ;
SUSSMAN, J ;
HAUDENSCHILD, C ;
EZEKOWITZ, MD .
CIRCULATION, 1989, 80 (04) :1029-1040
[8]  
Schwartz Robert S, 2002, Rev Cardiovasc Med, V3 Suppl 5, pS4
[9]   RESTENOSIS AND THE PROPORTIONAL NEOINTIMAL RESPONSE TO CORONARY-ARTERY INJURY - RESULTS IN A PORCINE MODEL [J].
SCHWARTZ, RS ;
HUBER, KC ;
MURPHY, JG ;
EDWARDS, WD ;
CAMRUD, AR ;
VLIETSTRA, RE ;
HOLMES, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :267-274
[10]   The Watanabe heritable hyperlipidemic rabbit as a suitable experimental model to study differences in tissue response between intimal and medial injury after balloon angioplasty [J].
Takagi, M ;
Ueda, M ;
Becker, AE ;
Takeuchi, K ;
Takeda, T .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (12) :3611-3619