New prostheses for use in bypass grafts with special emphasis on polyurethanes

被引:148
作者
Tiwari, A
Salacinski, H
Seifalian, AM
Hamilton, G
机构
[1] Univ London Royal Free Hosp, Tissue Engn Ctr, London NW3 2QG, England
[2] UCL, Royal Free & Univ Colll Med Sch, London, England
来源
CARDIOVASCULAR SURGERY | 2002年 / 10卷 / 03期
关键词
polyurethane; vascular prostheses; intimal hyperplasia; compliance; tissue engineering;
D O I
10.1016/S0967-2109(02)00004-2
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Vascular bypass procedures using traditional prosthetic grafts such as polytetrafluoroethylen (PTFE) and polyethylene tetraphthlate (Dacron) are prone to failure when used in low flow states such as in below knee bypass and when the diameter of the graft is less than 6 mm. A major factor in this is compliance mismatch between the graft and the diseased vessel, which may cause intimal hyperplasia at the distal anastomosis. PTFE and Dacron are rigid grafts with poor compliance. By improving the compliance of the prosthetic graft it is hoped that patency will improve. Recent advances in polyurethane chemistry have developed materials that do not degrade and which allow compliance matching of the graft to the patient's vasculature. It is now possible to manufacture biologically and haemodynamically compatible grafts with small diameter from these polyurethane graft materials. This review will focus on the lack of compliance in current vascular bypass grafts and the promise of the new polyurethane polymers in a new generation of small-bore bypass grafts. (C) 2002 The International Society for Cardiovascular Surgery. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 69 条
[1]
Prosthetic above-knee femoropopliteal bypass grafting: Results of a multicenter randomized prospective trial [J].
Abbott, WM ;
Green, RM ;
Matsumoto, T ;
Wheeler, JR ;
Miller, N ;
Veith, FJ ;
Suggs, WD ;
Hollier, L ;
Money, S ;
Garrett, HE ;
Moore, WS ;
Dean, RH ;
Cronenwett, JL ;
Carter, S ;
Greenhalgh, RM ;
ODonnell, TF .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (01) :19-28
[2]
EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[3]
Aldenhoff YBJ, 2001, J BIOMED MATER RES, V54, P224, DOI 10.1002/1097-4636(200102)54:2<224::AID-JBM9>3.0.CO
[4]
2-E
[5]
Australian multicentre evaluation of a new polyurethane vascular access graft [J].
Allen, RDM ;
Yuill, E ;
Nankivell, BJ ;
Francis, DMA .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1996, 66 (11) :738-742
[6]
Inflammatory response to implants [J].
Anderson, J.M. .
ASAIO Transactions, 1988, 34 (02) :101-107
[7]
Development of intimal hyperplasia in six different vascular prostheses [J].
Ao, PY ;
Hawthorne, WJ ;
Vicaretti, M ;
Fletcher, JP .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (03) :241-249
[8]
Bell PRF, 1998, CARDIOVASC SURG, V6, P17
[9]
BENNION RS, 1985, SURG GYNECOL OBSTET, V160, P239
[10]
BERGAN JJ, 1982, SURGERY, V92, P921