Medical device tracking: Results of a case study of the implantable cardioverter defibrillator

被引:4
作者
Kaczmarek, RG
Beaulieu, MD
Kessler, LG
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20850 USA
[2] St Jude Med Cardiac Rhythm Management Div, Sylmar, CA USA
关键词
D O I
10.1016/S0002-9149(99)00816-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Case reports were received of a fatal tachycardia caused by a malfunction of an implantable cardioverter defibrillator (ICD), a device that is subject to the tracking regulations of the Food and Drug Administration's Center for Devices and Radiological Health. The case reports led to a decision to notify 5,604 patients of the need for reprogramming of their ICDs to prevent the tachycardia. In the first 60 days, a total of 98.7% of the patients were successfully located and their devices reprogrammed. Multiple logistic regression analysis wets conducted to examine an extensive array of factors that might have been related to the time to reprogramming. Patient-specific factors such as age, sex, and ejection fraction did not serve as a barrier to reprogramming in the first week (p = NS). patients whose regular physician had >5 patients with the ICD subject to the recall were significantly more likely to have their ICDs reprogrammed in the first week (odds ratio [OR] 2.11, 95% confidence interval [CI] 1.85 to 2.43, p <0.001). Patients who changed physicians were significantly less likely to undergo reprogramming in the first week (OR 0.73, 95% CI 0.63 to 0.86, p <0.001). The experience of the recall of this tracked device is highly encouraging because it demonstrates that most tracked device recipients can be successfully located and receive medical intervention. Although tracking devices is a manufacturer's responsibility, the clinical community plays a critical role in its success. This report highlights the importance of understanding that role among physicians. (C)2000 by Excerpta Medico, Inc.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 6 条
[1]  
BRAUNWALD E, 1992, HEART DIS TXB CARDIO, P419
[2]   OUTLET STRUT FRACTURE OF A BJORK-SHILEY PROSTHESIS IN THE MITRAL POSITION [J].
FENNERTY, MB ;
PICK, RA ;
CLARK, MA .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (07) :923-924
[3]   STRUT FRACTURE IN THE BJORK-SHILEY MITRAL-VALVE PROSTHESIS - 2 CASE-REPORTS [J].
GOERTTLER, U ;
KAISERMARTINI, R .
THORACIC AND CARDIOVASCULAR SURGEON, 1984, 32 (05) :320-321
[4]  
IBARRA F, 1984, J THORAC CARDIOV SUR, V87, P315
[5]   Likelihood of underreporting of outlet strut fracture from examination of the Dutch Bjork-Shiley cc cohort [J].
Kallewaard, M ;
Algra, A ;
Defauw, J ;
Grobbee, D ;
van der Graaf, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (06) :768-773
[6]  
LOWE N, 1993, HHS PUBLICATION FDA, P1