Assessment of chromatographic peak purity by means of artificial neural networks

被引:13
作者
Hu, YZ
Zhou, GW
Kang, JH
Du, YX
Huang, F
Ge, JH
机构
[1] Department of Analytical Chemistry, China Pharmaceutical University
基金
中国国家自然科学基金;
关键词
peak purity; artificial neural networks; chemometrics;
D O I
10.1016/0021-9673(95)01303-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved chemometric approach is proposed for assessing chromatographic peak purity by means of artificial neural networks. A non-linear transformation function with a back-propagation algorithm was used to describe and predict the chromatographic data. The Mann-Whitney U-test was used for the concluding the purity of the chromatographic peak. Simulation data and practical analytical data for both pure and mixture samples were analysed with satisfactory results. A prior knowledge of the impurity and the related compound is unnecessary when a slight difference between their chromatogram and spectrum exists. The performance on simulated data sets by this approach was compared with the results from principal component analysis.
引用
收藏
页码:259 / 270
页数:12
相关论文
共 28 条
[1]   PREDICTION OF INFRARED-SPECTRA FROM CHEMICAL STRUCTURES OF ORGANIC-COMPOUNDS USING NEURAL NETWORKS [J].
AFFOLTER, C ;
CLERC, JT .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1993, 21 (2-3) :151-157
[2]   COMPARISON OF THE TRAINING OF NEURAL NETWORKS FOR QUANTITATIVE X-RAY-FLUORESCENCE SPECTROMETRY BY A GENETIC ALGORITHM AND BACKWARD ERROR PROPAGATION [J].
BOS, M ;
WEBER, HT .
ANALYTICA CHIMICA ACTA, 1991, 247 (01) :97-105
[3]  
BOSS A, 1992, ANAL CHIM ACTA, V256, P133
[4]   ASSESSMENT OF CHROMATOGRAPHIC PEAK PURITY BY MEANS OF MULTIWAVELENGTH DETECTION AND CORRELATION-BASED ALGORITHMS [J].
CASTLEDINE, JB ;
FELL, AF ;
MODIN, R ;
SELLBERG, B .
JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2) :27-36
[5]   PEAK TRACKING WITH A NEURAL NETWORK FOR SPECTRAL RECOGNITION [J].
COENEGRACHT, PMJ ;
METTING, HJ ;
VANLOO, EM ;
SNOEIJER, GJ ;
DOORNBOS, DA .
JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2) :145-160
[6]   IMPLEMENTATION AND EFFICIENCY OF AN AUTOMATIC PEAK-PURITY-CONTROL PROCEDURE IN HPLC-UV-VIS-COUPLING BASED ON PRINCIPAL COMPONENT ANALYSIS [J].
EBEL, S ;
MUECK, W .
CHROMATOGRAPHIA, 1988, 25 (12) :1075-1086
[7]   NOVEL TECHNIQUES FOR PEAK RECOGNITION AND DECONVOLUTION BY COMPUTER-AIDED PHOTODIODE ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :123-140
[8]  
FOLEY JP, 1984, J CHROMATOGR SCI, V22, P44
[9]   DECONVOLUTION OF OVERLAPPING CHROMATOGRAPHIC PEAKS USING A CEREBELLAR MODEL ARITHMETIC COMPUTER NEURAL NETWORK [J].
GALLANT, SR ;
FRALEIGH, SP ;
CRAMER, SM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1993, 18 (01) :41-57
[10]   CONDITIONS FOR DETECTING OVERLAPPED PEAKS WITH PRINCIPAL COMPONENT ANALYSIS IN HYPHENATED CHROMATOGRAPHIC METHODS [J].
GEMPERLINE, PJ ;
HAMILTON, JC .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2240-2243