Comparison of cyclophilin binding assay and radioimmunoassay in monitoring of blood cyclosporine

被引:7
作者
Huupponen, R [1 ]
Hirvisalo, EL [1 ]
Neuvonen, P [1 ]
机构
[1] UNIV HELSINKI,DEPT CLIN PHARMACOL,SF-00250 HELSINKI,FINLAND
关键词
cyclosporine; cyclophilin; cyclophilin binding; radioimmunoassay; therapeutic drug monitoring;
D O I
10.1097/00007691-199708000-00014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Cyclosporine binds with cyclophilin, an abundant protein found in almost all tissues, and the resulting complex interacts with calcineurin diminishing T-cell activation. Cyclophilin can be regarded as a cellular ''receptor'' for cyclosporine. Measuring cyclosporine binding to cyclophilin may offer a link between pharmacokinetics and pharmacodynamics that could improve monitoring of cyclosporine therapy. The authors investigated the feasibility of the cyclophilin binding assay and compared the results with a standard specific monoclonal radioimmunoassay in 100 blood samples taken for therapeutic drug monitoring. The results obtained with these methods were related closely with each other (r = 0.96; p < 0.001) but the mean (+/-SEM) concentrations were approximately two-fold higher in cyclophilin binding assay than in radioimmunoassay (520.4 +/- 49.9 ng/ml versus 257.7 +/- 28.6 ng/ml, respectively, p < 0.001). The shapes of the cyclosporine concentration versus time curves in two patients after a liver and heart transplantation, respectively, were similar after both methods but cyclophilin binding assay gave higher values than radioimmunoassay. Before firm conclusions on the clinical value of cyclophilin binding assay can be made, comparative studies in patients linking cyclosporine concentrations measured with cyclophilin binding assay and standard methods to the therapeutic outcome are needed.
引用
收藏
页码:446 / 449
页数:4
相关论文
共 17 条
[1]  
AGARWAL RP, 1987, CLIN CHEM, V33, P481
[2]   PHARMACOKINETICS OF ORALLY AND INTRAVENOUSLY ADMINISTERED CYCLOSPORINE IN PRE-KIDNEY TRANSPLANT PATIENTS [J].
AWEEKA, FT ;
TOMLANOVICH, SJ ;
PRUEKSARITANONT, T ;
GUPTA, SK ;
BENET, LZ .
JOURNAL OF CLINICAL PHARMACOLOGY, 1994, 34 (01) :60-67
[3]  
CLIPSTONE NA, 1993, ANN NY ACAD SCI, V696, P20
[4]   A RADIORECEPTOR ASSAY FOR THE MEASUREMENT OF CYCLOSPORINE ACTIVITY - A PRELIMINARY-REPORT [J].
DONNELLY, JG ;
SOLDIN, SJ .
THERAPEUTIC DRUG MONITORING, 1989, 11 (06) :696-700
[5]  
FAHR A, 1990, TRANSPLANT P, V22, P1116
[6]   CYCLOSPORINE CLINICAL PHARMACOKINETICS [J].
FAHR, A .
CLINICAL PHARMACOKINETICS, 1993, 24 (06) :472-495
[7]   INVITRO IMMUNOSUPPRESSIVE PROPERTIES OF CYCLOSPORINE METABOLITES [J].
FREED, BM ;
ROSANO, TG ;
LEMPERT, N .
TRANSPLANTATION, 1987, 43 (01) :123-127
[8]   A REVIEW OF ASSAY-METHODS FOR CYCLOSPORINE - CLINICAL IMPLICATIONS [J].
KIVISTO, KT .
CLINICAL PHARMACOKINETICS, 1992, 23 (03) :173-190
[9]  
LORBER MI, 1990, TRANSPLANT P, V22, P1240
[10]   CYCLOSPORINE-A MONITORING IN AUSTRALIA - CONSENSUS RECOMMENDATIONS [J].
MORRIS, RG ;
TETT, SE ;
RAY, JE .
THERAPEUTIC DRUG MONITORING, 1994, 16 (06) :570-576