Gas chromatography with inductively coupled plasma mass spectrometric detection in speciation analysis

被引:85
作者
Bouyssiere, B [1 ]
Szpunar, J [1 ]
Lobinski, R [1 ]
机构
[1] CNRS, UMR 5034, F-64053 Pau, France
关键词
gas chromatography; inductively coupled plasma mass spectrometry; speciation; organometallic compounds; review;
D O I
10.1016/S0584-8547(02)00024-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The state-of-the-art of gas chromatography coupled with inductively coupled plasma mass spectrometry (GC-ICP MS) is comprehensively reviewed. Particular attention is given to the recent advances in ICP MS detection including: GC-ICP interface designs; low power plasmas; and alternative mass analyzers (time-of-flight, double-focussing single collector, double-focussing and collision cell single-focussing multicollectors). On the level of sample preparation for speciation analysis by GC-ICP MS, new derivatization reagents and advances in extraction techniques, such as capillary purge-and-trap, solid phase microextraction and stirbar solid phase extraction are discussed. The increasing role of organometallic species labeled with stable isotopes for the detection of sources of errors during sample preparation and for isotope dilution quantification is highlighted. Applications of GC-ICP MS to the analysis of real-world samples are summarized with a focus on the areas which particularly benefit from the high ICP MS detection sensitivity and tolerance to sample matrix. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:805 / 828
页数:24
相关论文
共 122 条
[1]   Speciation of organotins in environmental samples by SPME-GC: comparison of four specific detectors: FPD, PFPD, MIP-AES and ICP-MS [J].
Aguerre, S ;
Lespes, G ;
Desauziers, V ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :263-269
[2]   Sampling and probing volatile metal(loid) species in natural waters by in-situ purge and cryogenic trapping followed by gas chromatography and inductively coupled plasma mass spectrometry (P-CT-GC-ICP/MS) [J].
Amouroux, D ;
Tessier, E ;
Pécheyran, C ;
Donard, OFX .
ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) :241-254
[3]  
Andrewes P, 1999, APPL ORGANOMET CHEM, V13, P659, DOI 10.1002/(SICI)1099-0739(199909)13:9<659::AID-AOC895>3.3.CO
[4]  
2-A
[5]  
Armstrong HL, 1999, ANAL CHIM ACTA, V390, P245
[6]   Comparison of three coupled gas chromatographic detectors (MS, MIP-AES, ICP-TOFMS) for organolead speciation analysis [J].
Baena, JR ;
Gallego, M ;
Valcárcel, M ;
Leenaers, J ;
Adams, FC .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3927-3934
[7]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[8]  
2-4
[9]   An alternative GC-ICP-MS interface design for trace element speciation [J].
Bayón, MM ;
Camblor, MG ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1317-1322
[10]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261