Cloud point preconcentration and flame atomic absorption spectrometric determination of Cd and Pb in human hair

被引:174
作者
Manzoori, JL [1 ]
Bavili-Tabrizi, A [1 ]
机构
[1] Tabriz Univ, Fac Chem, Dept Analyt Chem, Tabriz, Iran
关键词
cloud point preconcentration; flame atomic absorption spectrometry; Cd determination; Pb determination; Triton X-114; hair;
D O I
10.1016/S0003-2670(02)00765-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cloud point methodology has been successfully used for the preconcentration of trace amounts of Cd and Pb as a prior step to their determination by flame atomic absorption spectrometry. O,O-Diethyldithiophosphate and Triton X-114 are used as hydrophobic ligand and non-ionic surfactant, respectively. After phase separation at 40degreesC based on cloud point of the mixture, the surfactant-rich phase is diluted with methanol. The enriched analyte in the final solution is determined by flame atomic absorption spectrometry using conventional nebulization. After optimization of the complexation and extraction conditions, enhancement factors of 22 and 43 were obtained for Cd and Pb, respectively. Under the experimental conditions used, preconcentration of only 10 ml of sample in the presence of 0.05% (v/v) Triton X-114 permitted the detection of 0.62 mug l(-1) of Cd and 2.86 mug l(-1) of Pb. The proposed method was applied to the determination of Cd and Pb inhuman hair samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 33 条
[1]   1,10-phenanthroline as a complexing agent for on-line sorbent extraction preconcentration for flow injection-flame atomic absorption spectrometry [J].
Ali, A ;
Yin, XF ;
Shen, H ;
Ye, YX ;
Gu, X .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :283-289
[2]   Slurry sampling electrothermal atomic absorption spectrometric determination of lead, cadmium and manganese in human hair samples using rapid atomizer programs [J].
BermejoBarrera, P ;
MoredaPineiro, A ;
MoredaPineiro, J ;
BermejoBarrera, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :301-306
[3]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[4]   CLOUD POINT TRANSITION IN NONIONIC MICELLAR SOLUTIONS [J].
CORTI, M ;
MINERO, C ;
DEGIORGIO, V .
JOURNAL OF PHYSICAL CHEMISTRY, 1984, 88 (02) :309-317
[5]   HYDROLYSIS OF THE O,O-DIALKYL PHOSPHORODITHIOIC ACIDS USED AS EXTRACTANTS IN LIQUID-LIQUID SYSTEMS [J].
COTE, G ;
BAUER, D .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :2153-2157
[6]   Determination of Ag and Au in geological samples by flame atomic absorption spectrometry after cloud point extraction [J].
da Silva, MAM ;
Frescura, VLA ;
Aguilera, FJN ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) :1369-1373
[7]  
da Silva MAM, 2001, SPECTROCHIM ACTA B, V56, P1941
[8]  
da Silva MAM, 2000, SPECTROCHIM ACTA B, V55, P803
[9]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[10]   Single-sample cloud point determination of iron, cobalt and nickel by flow injection analysis flame atomic absorption spectrometry - application to real samples and certified reference materials [J].
Giokas, DL ;
Paleologos, EK ;
Tzouwara-Karayanni, SM ;
Karayannis, MI .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :521-526