Chemotaxis assays of mouse sperm on microfluidic devices

被引:56
作者
Koyama, Sachiko
Amarie, Dragos
Soini, Helena A.
Novotny, Milos V. [1 ]
Jacobson, Stephen C.
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] Indiana Univ, Dept Phys, Bloomington, IN 47405 USA
[3] Indiana Univ, Inst Pheromone Res, Bloomington, IN 47405 USA
关键词
D O I
10.1021/ac052087i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sperm chemotaxis is an area of significant interest to scientists involved in reproductive science. Understanding how and when sperm cells are attracted to the egg could have profound effects on reproduction and contraception. In an effort to systematically study this problem, we have fabricated and evaluated a microfluidic device to measure sperm chemotaxis. The device was designed with a flowthrough configuration using a spatially and temporally stable chemical gradient. Mouse sperm cells were introduced into the chemotaxis chamber between confluent flows of mouse ovary extract and buffer. The sperm experiencing chemotaxis swam toward the extract and were counted relative to those that swam toward the buffer. The ovary extracts were diluted from 10(2) to 10(7) times, and each extract dilution was screened for chemotaxis. Four out of six ovaries showed a strong chemotactic response at extract dilutions of 10(-3) to 10(-5). This device provided a convenient, disposable platform on which to conduct chemotaxis assays, and the flow-through design overcomes difficulties associated with distinguishing chemotaxis from trapping.
引用
收藏
页码:3354 / 3359
页数:6
相关论文
共 47 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]  
BIGGERS J. D., 1971, Methods in mammalian embryology, P86
[3]   Passively driven integrated microfluidic system for separation of motile sperm [J].
Cho, BS ;
Schuster, TG ;
Zhu, XY ;
Chang, D ;
Smith, GD ;
Takayama, S .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1671-1675
[4]   SEQUENTIAL ACQUISITION OF CHEMOTACTIC RESPONSIVENESS BY HUMAN SPERMATOZOA [J].
COHENDAYAG, A ;
RALT, D ;
TURKASPA, I ;
MANOR, M ;
MAKLER, A ;
DOR, J ;
MASHIACH, S ;
EISENBACH, M .
BIOLOGY OF REPRODUCTION, 1994, 50 (04) :786-790
[5]   Diffusion coefficient measurements in microfluidic devices [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
TALANTA, 2002, 56 (02) :365-373
[6]   Generation of gradients having complex shapes using microfluidic networks [J].
Dertinger, SKW ;
Chiu, DT ;
Jeon, NL ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1240-1246
[7]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[8]  
Eisenbach M, 1999, BIOESSAYS, V21, P203, DOI 10.1002/(SICI)1521-1878(199903)21:3<203::AID-BIES4>3.0.CO
[9]  
2-T
[10]   Sperm chemotaxis [J].
Eisenbach, M .
REVIEWS OF REPRODUCTION, 1999, 4 (01) :56-66