Lower diagnostic accuracy of thallium-201 SPECT myocardial perfusion imaging in women: An effect of smaller chamber size

被引:92
作者
Hansen, CL
Crabbe, D
Rubin, S
机构
[1] Section of Cardiology, Temple University Hospital, Philadelphia, PA
[2] Section of Cardiology, Temple University Hospital, Philadelphia
关键词
D O I
10.1016/S0735-1097(96)00304-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We attempted to formally compare, the diagnostic accuracy of thallium-201 single-photon emission computed tomographic (SPECT) myocardial perfusion imaging in men and women and the effect of chamber size on accuracy. Background. The diagnostic accuracy of conventional exercise testing has been shown to be lower in women. Less is known about the relative accuracy of perfusion imaging. Because of smaller body size, women have a smaller heart size than men, a factor that may reduce accuracy. Methods. We identified 323 patients undergoing thallium-201 SPECT myocardial perfusion imaging who either had <5% probability of coronary artery disease (CAD) by Bayesian analysis or who underwent cardiac catheterization within 60 days of stress testing. Patients with documented history of infarction, coronary artery bypass grafting, pathologic Q-waves on the electrocardiogram, left bundle branch block or nonischemic cardiomyopathy were not included. We performed strict quantitative analysis,and receiver operating characteristic (ROC) curves were generated and the area under the curve was calculated for men and women. A size index was generated from the number of short-axis slices and average radius of each slice, and the group was classified as having a large or a small chamber size. The ROC areas of men and women with a large and a small chamber size were then compared. Results, Diagnostic accuracy was lower in women than in men (ROC area 0.82 vs. 0.93, p < 0.05) despite similar values for peak heart rate and rate-pressure product and similar severity of CAD. There was a greater difference in accuracy between patients with a large versus a small chamber size (ROC area 0.94 vs. 0.73, p < 0.01) despite similar levels of exercise and severity of CAD. When we compared men and women in groups stratified by chamber size, we could not detect a significant difference between ROC area values of men and women (large: 0,94 men, 0.93 women, p = 0.77, power to detect difference in area of 0.15 = 91%; small: 0.79 men, 0.72 women, p = 0.55, power to detect difference in area of 0.15 = 35%). Conclusions. The diagnostic accuracy of thallium SPECT myocardial perfusion imaging is lower in women than in men. Most of the difference appears to be due to smaller left ventricular chamber size in women, although a small residual gender effect in smaller heart sizes cannot be entirely excluded. It is proposed that the most likely cause for this difference is the relatively greater effect of imaging blurring on smaller hearts.
引用
收藏
页码:1214 / 1219
页数:6
相关论文
共 26 条
[1]  
*AM HEART ASS, 1996, HEART STROK FACTS 19
[2]   DIFFERENCES IN ELECTROCARDIOGRAPHIC RESPONSE TO EXERCISE OF WOMEN AND MEN - NON-BAYESIAN FACTOR [J].
BAROLSKY, SM ;
GILBERT, CA ;
FARUQUI, A ;
NUTTER, DO ;
SCHLANT, RC .
CIRCULATION, 1979, 60 (05) :1021-1027
[3]   IDENTIFICATION OF EXTENSIVE CORONARY-ARTERY DISEASE IN WOMEN BY EXERCISE SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC (SPECT) THALLIUM IMAGING [J].
CHAE, SC ;
HEO, JY ;
ISKANDRIAN, AS ;
WASSERLEBEN, V ;
CAVE, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (06) :1305-1311
[4]   QUANTITATIVE ROTATIONAL TL-201 TOMOGRAPHY FOR IDENTIFYING AND LOCALIZING CORONARY-ARTERY DISEASE [J].
DEPASQUALE, EE ;
NODY, AC ;
DEPUEY, EG ;
GARCIA, EV ;
PILCHER, G ;
BREDLAU, C ;
ROUBIN, G ;
GOBER, A ;
GRUENTZIG, A ;
DAMATO, P ;
BERGER, HJ .
CIRCULATION, 1988, 77 (02) :316-327
[5]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[6]  
Dorfman D. D., 1982, EVALUATION DIAGNOSTI, P212
[7]   THE INCONSISTENT PATTERN OF THALLIUM DEFECTS - A CLUE TO THE FALSE POSITIVE PERFUSION SCINTIGRAM [J].
DUNN, RF ;
WOLFF, L ;
WAGNER, S ;
BOTVINICK, EH .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (02) :224-232
[8]   EXERCISE TL-201 MYOCARDIAL SCINTIGRAPHY IN WOMEN - CORRELATION WITH CORONARY ARTERIOGRAPHY [J].
FRIEDMAN, TD ;
GREENE, AC ;
ISKANDRIAN, AS ;
HAKKI, AH ;
KANE, SA ;
SEGAL, BL .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (07) :1632-1637
[9]  
Gensini GG, 1975, CORONARY ARTERIOGRAP
[10]  
GERSON MC, 1994, J NUCL MED, V35, P580