Estimation of the shear stress on the surface of an aortic valve leaflet

被引:83
作者
Weston, MW
LaBorde, DV
Yoganathan, AP [1 ]
机构
[1] Georgia Inst Technol, Sch Biomed Engn, Inst Bioengn & Biosci, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Chem Engn, Inst Bioengn & Biosci, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
laser Doppler velocimetry; steady flow; polyurethane heart valve; boundary layer; tissue engineering; bioreactor development;
D O I
10.1114/1.199
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The limited durability of xenograft heart valves and the limited supply of allografts have sparked interest in tissue engineered replacement values. A bioreactor for tissue engineered valves must operate at conditions that optimize the biosynthetic abilities of seeded cells while promoting their adherence to the leaflet matrix. An important parameter is sheer stress, which is known to influence cellular behavior and may thus be crucial in bioreactor optimization. Therefore, an accurate estimate of the shear stress on the leaflet surface would not only improve our understanding of the mechanical environment of aortic valve leaflets, but it would also aid in bioreactor design. To estimate the shear stress on the leaflet surface, two-component laser-Doppler velocimetry measurements have been conducted inside a transparent polyurethane valve with a trileaflet structure similar to the native aortic valve. Steady how rates of 7.5, 15.0, and 22.5 L/min were examined to cover the complete range possible during the cardiac cycle. The laminar shear stresses were calculated by linear regression of four axial velocity measurements near the surface of the leaflet. The maximum shear stress recorded was 79 dgne/cm(2), in agreement with boundary layer theory and previous experimental and computational studies. This study has provided a range of shear stresses to be explored in bioreactor design and has defined a maximum shear stress at which cells must remain adherent upon a tissue engineered construct. (C) 1999 Biomedical Engineering Society. [S0090-6964(99)01004-8].
引用
收藏
页码:572 / 579
页数:8
相关论文
共 21 条
[1]   12-YEAR COMPARISON OF A BJORK-SHILEY MECHANICAL HEART-VALVE WITH PORCINE BIOPROSTHESES [J].
BLOOMFIELD, P ;
WHEATLEY, DJ ;
PRESCOTT, RJ ;
MILLER, HC .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09) :573-579
[2]   LASER ANEMOMETRY MEASUREMENTS OF PULSATILE FLOW PAST AORTIC-VALVE PROSTHESES [J].
CHANDRAN, KB ;
CABELL, GN ;
KHALIGHI, B ;
CHEN, CJ .
JOURNAL OF BIOMECHANICS, 1983, 16 (10) :865-873
[3]  
Corden J, 1995, Proc Inst Mech Eng H, V209, P243, DOI 10.1243/PIME_PROC_1995_209_351_02
[4]  
Curtil A, 1997, J HEART VALVE DIS, V6, P296
[5]   ENDOTHELIAL-CELL ORIENTATION ON AORTIC-VALVE LEAFLETS [J].
DECK, JD .
CARDIOVASCULAR RESEARCH, 1986, 20 (10) :760-767
[6]   WALL SHEAR-STRESS DISTRIBUTION ALONG THE CUSP OF A TRI-LEAFLET PROSTHETIC VALVE [J].
EINAV, S ;
STOLERO, D ;
AVIDOR, JM ;
ELAD, D ;
TALBOT, L .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (01) :13-18
[7]   DERIVATION OF SHEER RATES FROM NEAR-WALL LDA MEASUREMENTS UNDER STEADY AND PULSATILE FLOW CONDITIONS [J].
FATEMI, RS ;
RITTGERS, SE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03) :361-368
[10]   INVITRO FLOW DYNAMICS OF 4 PROSTHETIC AORTIC VALVES - A COMPARATIVE-ANALYSIS [J].
HANLE, DD ;
HARRISON, EC ;
YOGANATHAN, AP ;
ALLEN, DT ;
CORCORAN, WH .
JOURNAL OF BIOMECHANICS, 1989, 22 (6-7) :597-607