Determination of cyclic organic acid anhydrides in air using gas chromatography .2. Sampling and determination of hexahydrophthalic anhydride, methylhexahydrophthalic anhydride, tetrahydrophthalic anhydride and octenylsuccinic anhydride

被引:13
作者
Jonsson, BAG [1 ]
Lindh, CH [1 ]
Gustavsson, CA [1 ]
Welinder, H [1 ]
Pfaffli, P [1 ]
机构
[1] INST OCCUPAT HLTH,FIN-00250 HELSINKI,FINLAND
关键词
hexahydrophthalic; methylhexahydrophthalic; tetrahydrophthalic and octenylsuccinic anhydride; air; work environment; solid sorbent; bubbler; impinger and glass-fibre filter sampling;
D O I
10.1039/an9962101285
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methods for sampling and determination of four organic acid anhydrides are described. The methods were validated in a standard atmosphere and in the work environment, Hexahydrophthalic anhydride (HHPA), methylhexahydrophthalic anhydride (MHHPA), tetrahydrophthalic anhydride (THPA) and octenylsuccinic anhydride (OSA) were sampled using Tenax and Amberlite XAD-2 solid sorbents and determined by GC; with flame ionization detection (FID) after elution, The precision was normally better than 10% but for OSA it was up to 19%, The detection limits were 0.1 mu g per sample. MHHPA, THPA and OSA were also sampled using bubblers containing aqueous sampling solutions, MHHPA and THPA was derivatized with pentafluorobenzyl bromide (PFBBr) and determined by GC with MS detection, OSA was derivatized by methanol with boron trifluoride catalysis and determined by GC-FID. The precisions for MHHPA and THPA were 4 and 8%, respectively, and the detection limit was < 0.005 mu g per sample. The precision for OSA was up to 58% and the detection limit was 0.2 mu g per sample. HHPA and MHHPA were also sampled on glass-fibre filters, derivatized with PFBBr, and determined by GC-MS with good results. However, further validations of the filter methods are needed.
引用
收藏
页码:1285 / 1290
页数:6
相关论文
共 8 条
[1]   DETERMINATION OF HEXAHYDROPHTHALIC ANHYDRIDE IN AIR USING GAS-CHROMATOGRAPHY [J].
JONSSON, B ;
WELINDER, H ;
SKARPING, G .
JOURNAL OF CHROMATOGRAPHY, 1991, 558 (01) :247-256
[2]   Determination of cyclic organic acid anhydrides in air using gas chromatography .1. A review [J].
Jonsson, BAG ;
Welinder, H ;
Pfaffli, P .
ANALYST, 1996, 121 (09) :1279-1284
[3]  
JONSSON BAG, 1984, AM IND HYG ASSOC J, V55, P330
[4]  
KESKINEN H, 1988, NEW ENGL REG ALLERGY, V19, P397
[5]   DETERMINATION OF CARBOXYLIC-ACIDS IN BIOLOGICAL SAMPLES AS THEIR TRICHLOROETHYL ESTERS BY GAS-CHROMATOGRAPHY [J].
PFAFFLI, P ;
SAVOLAINEN, H ;
KESKINEN, H .
CHROMATOGRAPHIA, 1989, 27 (9-10) :483-488
[6]  
VENABLES KM, 1989, BRIT J IND MED, V46, P222
[7]   SPECIFIC ANTIBODIES TO METHYLTETRAHYDROPHTHALIC ANHYDRIDE IN EXPOSED WORKERS [J].
WELINDER, H ;
NIELSEN, J ;
GUSTAVSSON, C ;
BENSRYD, I ;
SKERFVING, S .
CLINICAL AND EXPERIMENTAL ALLERGY, 1990, 20 (06) :639-645
[8]   EXPOSURE-RESPONSE RELATIONSHIPS IN THE FORMATION OF SPECIFIC ANTIBODIES TO HEXAHYDROPHTHALIC ANHYDRIDE IN EXPOSED WORKERS [J].
WELINDER, HE ;
JONSSON, BA ;
NIELSEN, JE ;
OTTOSSON, HE ;
GUSTAVSSON, CA .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1994, 20 (06) :459-465