Radiation Dose Comparison Between 70 kVp and 100 kVp With Spectral Beam Shaping for Non-Contrast-Enhanced Pediatric Chest Computed Tomography A Prospective Randomized Controlled Study

被引:61
作者
Weis, Meike [1 ]
Henzler, Thomas [1 ]
Nance, John W., Jr. [2 ]
Haubenreisse, Holger [1 ]
Meyer, Mathias [1 ]
Sudarski, Sonja [1 ]
Schoenberg, Stefan O. [1 ]
Neff, K. Wolfgang [1 ]
Hagelstein, Claudia [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
[2] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
chest CT; pediatric CT; low-dose CT; spectral shaping; low peak kilovoltage imaging; DUAL-SOURCE CT; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; ANGIOGRAPHY; ANESTHESIA;
D O I
10.1097/RLI.0000000000000325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objective: The aim of this prospective randomized controlled study was to compare 2 techniques for radiation dose reduction in non-contrast-enhanced pediatric chest computed tomography (CT): low peak kilovoltage imaging at 70 kVp and spectral beam shaping at 100 kVp using a dedicated tin filter (100-kVp Sn). Materials and Methods: All chest CT examinations were performed on a third generation dual-source CT system (SOMATOM Force; Siemens Healthineers, Germany). Fifty children (mean age, 6.8 +/- 5.1 years) were examined using the 100-kVp Sn protocol, whereas 25 children received the 70-kVp protocol (mean age, 5.7 +/- 5.2 years; 2: 1 randomization scheme). Radiation metrics and organ doses were compared between acquisition techniques using commercially available radiation dose analysis software (Radimetrics Inc, Bayer AG, Toronto, Ontario, Canada). Objective image quality, expressed by signal-tonoise ratio and subjective image quality based on a 4-point scale (1, best; 4, worst image quality), were compared. Results: Volume CT dose index and size-specific dose estimate were significantly lower in the 100-kVp Sn group compared with the 70-kVp group (0.19 +/- 0.12 mGy vs 0.81 +/- 0.70 mGy and 0.34 +/- 0.13 mGy vs 1.48 +/- 1.11 mGy; P < 0.0001 for both). Accordingly, mean effective dose was significantly lower for the 100-kVp Sn examinations (0.21 +/- 0.10 mSv) compared with the 70-kVp examinations (0.83 +/- 0.49 mSv; P < 0.0001). Calculated organ doses were also significantly lower using the 100-kVp Sn protocol when compared with the 70-kVp protocol; for example, breast dose was reduced by a factor of 4.3. Signal-to-noise ratio was slightly superior for 70-kVp images while lung image quality of the 100-kVp Sn protocol was preferred in subjective analysis (P = 0.0004). Conclusions: Pediatric chest CT performed at 100 kVp with an additional tin filter for spectral shaping significantly reduces radiation dose when compared with low peak kilovoltage imaging at 70 kVp and therefore should be preferred in non-contrast-enhanced pediatric chest CT examinations, particularly (given the improved subjective image quality) when the main focus is evaluation of the lung parenchyma.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 30 条
[1]
Image Quality of Low-Energy Pulmonary CT Angiography: Comparison With Standard CT [J].
Bogot, Naama R. ;
Fingerle, Alexander ;
Shaham, Dorith ;
Nissenbaum, Izhak ;
Sosna, Jacob .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) :W273-W278
[2]
Boone J.M., 2011, SIZE SPECIFIC DOSE E
[3]
Justifying referrals for paediatric CT [J].
Brady, Zoe ;
Cain, Timothy M. ;
Johnston, Peter N. .
MEDICAL JOURNAL OF AUSTRALIA, 2012, 197 (02) :95-98
[4]
Braun FM, 2014, EUR RADIOL
[5]
Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility [J].
Braun, Franziska M. ;
Johnson, Thorsten R. C. ;
Sommer, Wieland H. ;
Thierfelder, Kolja M. ;
Meinel, Felix G. .
EUROPEAN RADIOLOGY, 2015, 25 (06) :1598-1606
[6]
Cristy M., 1987, NUREGCR1159
[7]
Anesthesia and the developing brain: a way forward for clinical research [J].
Davidson, Andrew J. ;
Becke, Karin ;
de Graaff, Jurgen ;
Giribaldi, Gaia ;
Habre, Walid ;
Hansen, Tom ;
Hunt, Rodney W. ;
Ing, Caleb ;
Loepke, Andreas ;
McCann, Mary Ellen ;
Ormond, Gillian D. ;
Prato, Alessio Pini ;
Salvo, Ida ;
Sun, Lena ;
Vutskits, Laszlo ;
Walker, Suellen ;
Disma, Nicola .
PEDIATRIC ANESTHESIA, 2015, 25 (05) :447-452
[8]
Pulmonary Disease in Cystic Fibrosis: Assessment with Chest CT at Chest Radiography Dose Levels [J].
Ernst, Caroline W. ;
Basten, Ines A. ;
Ilsen, Bart ;
Buls, Nico ;
Van Gompel, Gert ;
De Wachter, Elke ;
Nieboer, Koenraad H. ;
Verhelle, Filip ;
Malfroot, Anne ;
Coomans, Danny ;
De Maeseneer, Michel ;
de Mey, Johan .
RADIOLOGY, 2014, 273 (02) :597-605
[9]
Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule Detection First Performance Evaluation of Single Energy Scanning With Spectral Shaping [J].
Gordic, Sonja ;
Morsbach, Fabian ;
Schmidt, Bernhard ;
Allmendinger, Thomas ;
Flohr, Thomas ;
Husarik, Daniela ;
Baumueller, Stephan ;
Raupach, Rainer ;
Stolzmann, Paul ;
Leschka, Sebastian ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2014, 49 (07) :465-473
[10]
Hagelstein C, 2015, Z MED PHYS