Evaluation of automated immunoassays for 25(OH)-vitamin D determination in different critical populations before and after standardization of the assays

被引:63
作者
Cavalier, Etienne [1 ]
Lukas, Pierre [1 ]
Crine, Yannick [1 ]
Peeters, Stephanie [1 ]
Carlisi, Agnes [1 ]
Le Goff, Caroline [1 ]
Gadisseur, Romy [1 ]
Delanaye, Pierre [2 ]
Souberbielle, Jean-Claude [3 ]
机构
[1] Univ Liege, CHU Sart Tilman, Dept Clin Chem, B-4000 Liege, Belgium
[2] Univ Liege, CHU Sart Tilman, B-4000 Liege, Belgium
[3] Hop Necker Enfants Malad, Lab Explorat Fonct, Paris, France
关键词
Vitamin D; Standardization; Vitamin D-binding protein; Uremia; 25-HYDROXYVITAMIN D ASSAYS; D-BINDING PROTEIN; VITAMIN-D STATUS; MASS-SPECTROMETRY; ACCURACY;
D O I
10.1016/j.cca.2014.01.026
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Standardization of immunoassays for 25(OH)-vitamin D determination is a major problem in clinical practice. A worldwide standardization program has started to address this and will reduce the bias observed between immunoassays. We aimed to calibrate 5 immunoassays on a LC-MS/MS traceable to the SRM 2972 and the ID-LC-MS/MS 25(OH)D Reference Method Procedure to see if the re-standardization would be efficient in a population of 3rd trimester pregnant women (PW), hemodialysis (HD) and osteoporosis (OP) patient. Material and methods: 184 serum samples (25(OH)D: 8.4-87 ng/ml) were selected to calibrate the immunoassays (Abbott-Architect, Roche-Elecsys, DiaSorin-Liaison, Siemens-Centaur and IDS-iSYS). Chromsystems MassChrom method was used as the referenced. Serum obtained in 34 PW, 25 HD and 34 OP patients were used as comparatives. Results: After adjusting to LC-MS/MS, immunoassays had regression slopes nearly identical to 1.0 with intercepts <0.5 ng/ml. However, in special populations, a systematic bias was still observed, except for iSYS. Conclusions: Re-standardization of 25(OH)D immunoassay will globally improve the differences. However, patients with a different serum matrix will still present significantly different results when they will be run with different methods. For those patients, the LC-MS/MS method seems to be the method of choice, even if some immunoassays are less influenced than others. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 10 条
[1]   Cross-reactivity of 25-hydroxy vitamin D2 from different commercial immunoassays for 25-hydroxy vitamin D: an evaluation without spiked samples [J].
Cavalier, Etienne ;
Wallace, A. Michael ;
Carlisi, Agnes ;
Chapelle, Jean-Paul ;
Delanaye, Pierre ;
Souberbielle, Jean-Claude .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (03) :555-558
[2]   Human anti-animal interference in DiaSorin Liaison total 25(OH)-vitamin D assay: Towards the end of a strange story? [J].
Cavalier, Etienne ;
Carlisi, Agnes ;
Bekaert, Anne-Catherine ;
Rousselle, Olivier ;
Chapelle, Jean-Paul .
CLINICA CHIMICA ACTA, 2012, 413 (3-4) :527-528
[3]   Accuracy of three automated 25-hydroxyvitamin D assays in hemodialysis patients [J].
Depreter, Barbara ;
Heijboer, Annemieke C. ;
Langlois, Michel R. .
CLINICA CHIMICA ACTA, 2013, 415 :255-260
[4]   Accuracy of 6 Routine 25-Hydroxyvitamin D Assays: Influence of Vitamin D Binding Protein Concentration [J].
Heijboer, Annemieke C. ;
Blankenstein, Marinus A. ;
Kema, Ido P. ;
Buijs, Madelon M. .
CLINICAL CHEMISTRY, 2012, 58 (03) :543-548
[5]   The measurement of 25-hydroxy vitamin D - an analytical challenge [J].
Herrmann, Markus .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (11) :1873-1875
[6]   Approaches to measurement of Vitamin D concentrations - Mass spectrometry [J].
Kobold, Uwe .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2012, 72 :54-59
[7]   Vitamin D-Binding Protein and Vitamin D Status of Black Americans and White Americans [J].
Powe, Camille E. ;
Evans, Michele K. ;
Wenger, Julia ;
Zonderman, Alan B. ;
Berg, Anders H. ;
Nalls, Michael ;
Tamez, Hector ;
Zhang, Dongsheng ;
Bhan, Ishir ;
Karumanchi, S. Ananth ;
Powe, Neil R. ;
Thadhani, Ravi .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (21) :1991-2000
[8]   Vitamin D status as an international issue: National surveys and the problem of standardization [J].
Sempos, Christopher T. ;
Vesper, Hubert W. ;
Phinney, Karen W. ;
Thienpont, Linda M. ;
Coates, Paul M. .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2012, 72 :32-40
[9]   Candidate Reference Measurement Procedures for Serum 25-Hydroxyvitamin D3 and 25-Hydroxyvitamin D2 by Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry [J].
Stepman, Hedwig C. M. ;
Vanderroost, An ;
Van Uytfanghe, Katleen ;
Thienpont, Linda M. .
CLINICAL CHEMISTRY, 2011, 57 (03) :441-448
[10]   Measurement of 25-hydroxyvitamin D in the clinical laboratory: Current procedures, performance characteristics and limitations [J].
Wallace, A. M. ;
Gibson, S. ;
de la Hunty, A. ;
Lamberg-Allardt, C. ;
Ashwell, M. .
STEROIDS, 2010, 75 (07) :477-488